	<entry>
		<id>https://ess-wiki.advantech.com.tw/wiki/index.php?title=Real_Application_Case&amp;diff=12721&amp;oldid=prev</id>
		<title>Hank.peng: Created page with &quot;= Real Application Case - ADAM-4117 =  '''&lt;span style=&quot;font-size:large;&quot;&gt;ADAM-4117 8-channel Analog Input Module&lt;/span&gt;'''  &lt;span style=&quot;font-size:larger;&quot;&gt;1. H.W. Environment...&quot;</title>
		<link rel="alternate" type="text/html" href="https://ess-wiki.advantech.com.tw/wiki/index.php?title=Real_Application_Case&amp;diff=12721&amp;oldid=prev"/>
				<updated>2018-08-07T03:06:21Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;= Real Application Case - ADAM-4117 =  &amp;#039;&amp;#039;&amp;#039;&amp;lt;span style=&amp;quot;font-size:large;&amp;quot;&amp;gt;ADAM-4117 8-channel Analog Input Module&amp;lt;/span&amp;gt;&amp;#039;&amp;#039;&amp;#039;  &amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;1. H.W. Environment...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;= Real Application Case - ADAM-4117 =&lt;br /&gt;
&lt;br /&gt;
'''&amp;lt;span style=&amp;quot;font-size:large;&amp;quot;&amp;gt;ADAM-4117 8-channel Analog Input Module&amp;lt;/span&amp;gt;'''&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;1. H.W. Environment &amp;amp; Configuration&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;[[File:Adam-4117-01.png|600x560px|Adam-4117-01.png]]&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2. Setup&amp;amp;nbsp;Modbus register from ADAM utility: AdamApax .NET Utility&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.1 Download&amp;amp;nbsp;AdamApax .NET Utility from URL [http://support.advantech.com/Support/DownloadSRDetail_New.aspx?SR_ID=1-2AKUDB&amp;amp;Doc_Source=Download http://support.advantech.com/Support/DownloadSRDetail_New.aspx?SR_ID=1-2AKUDB&amp;amp;Doc_Source=Download] and install it to your Gateway.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.2 Launch&amp;amp;nbsp;AdamApax .NET Utility,&amp;amp;nbsp;select COM port which ADAM module is connected, right click on the COM port you selected and click &amp;quot;Search Device&amp;quot; to detect your ADAM-4117.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-04.png|680x500px|Adam-4117-04.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.3 After ADAM-4117 appeared, click on it to check its settings or change the default settings for your H.W. configuration.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-06.png|680x500px|Adam-4117-06.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-07.png|680x500px|Adam-4117-07.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-08.png|680x500px|Adam-4117-08.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.4&amp;amp;nbsp;Provide a stable 12V voltage power to Vin0.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-10.jpg|600x600px|Adam-4117-10.jpg]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.5&amp;amp;nbsp;Check the value of Channel 0 from AdamApax .NET Utility, the value of Vin0 is 12.108V.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-11.png|680x500px|Adam-4117-11.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;2.6&amp;amp;nbsp;Check the value of Modbus Location 40001 from AdamApax .NET Utility, the value is 52900. ( 12.108 / 15 * 65536 = 52900.66 )&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[File:Adam-4117-12.png|680x500px|Adam-4117-12.png]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3. Gateway Modbus_Handler configuration&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3.1 Edit Modbus_Handler.ini for the ADAM's configuration.&amp;lt;/span&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;[Platform]&lt;br /&gt;
Interval=1&lt;br /&gt;
#Interval: The time delay between two modbus access round in second.&amp;amp;nbsp;&lt;br /&gt;
Delay=0&lt;br /&gt;
#Delay: The time delay between two modbus access in millisecond.&lt;br /&gt;
#Delay=0 means no delay.&lt;br /&gt;
Log=0&lt;br /&gt;
&lt;br /&gt;
Name=ADAM-4117&lt;br /&gt;
Protocol=Modbus_RTU&lt;br /&gt;
SlavePort=COM1&lt;br /&gt;
Baud=9600&lt;br /&gt;
Parity=None&lt;br /&gt;
DataBits=8&lt;br /&gt;
StopBits=1&lt;br /&gt;
SlaveID=1&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3.2 Edit Modbus_Handler.ini for ADAM-4117 modbus location configuration.&amp;lt;/span&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;[Holding Registers]&lt;br /&gt;
numberOfR=3&lt;br /&gt;
R0=0,Vin0,0,65535,1,V,0,&amp;quot;&amp;quot;&lt;br /&gt;
R1=1,Vin1,0,65535,1,V,0,&amp;quot;&amp;quot;&lt;br /&gt;
R2=2,Vin2,0,65535,1,V,0,&amp;quot;&amp;quot;&lt;br /&gt;
&lt;br /&gt;
;tag = offset, name, min, max, precision, unit, data type, lua script&lt;br /&gt;
&lt;br /&gt;
;tag&amp;amp;nbsp;&amp;amp;nbsp; &amp;amp;nbsp;Base Address&lt;br /&gt;
;B&amp;amp;nbsp;&amp;amp;nbsp; &amp;amp;nbsp;00001--&amp;gt;Coils&lt;br /&gt;
;IB&amp;amp;nbsp;&amp;amp;nbsp; &amp;amp;nbsp;10001--&amp;gt;Discrete Inputs&lt;br /&gt;
;IR&amp;amp;nbsp;&amp;amp;nbsp; &amp;amp;nbsp;30001--&amp;gt;Input Registers&lt;br /&gt;
;R&amp;amp;nbsp;&amp;amp;nbsp; &amp;amp;nbsp;40001--&amp;gt;Holding Registers&lt;br /&gt;
&lt;br /&gt;
;data type&lt;br /&gt;
;0-&amp;gt;16-bit operation&lt;br /&gt;
;1-&amp;gt;32-bit float no swap&lt;br /&gt;
;2-&amp;gt;32-bit float byte and word swap&lt;br /&gt;
;3-&amp;gt;32-bit float byte swap&lt;br /&gt;
;4-&amp;gt;32-bit float word swap&lt;br /&gt;
;5-&amp;gt;32-bit unsigned int no swap&lt;br /&gt;
;6-&amp;gt;32-bit unsigned int word swap&lt;br /&gt;
;7-&amp;gt;32-bit signed int no swap&lt;br /&gt;
;8-&amp;gt;32-bit signed int word swap&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3.2 Restart WISE Agent service from Task Manager, login RMM 3.3 to check the values that ADAM-4117 and Gateway uploaded.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;[[File:Adam-4117-13 modbus 1.0.png|800x600px|Adam-4117-13.png]]&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3.3&amp;amp;nbsp;Use Lua convert function to transfer modbus value to voltage value, open&amp;amp;nbsp;Modbus_Device0.ini and give Vin0~Vin2 Lua scripts&amp;amp;nbsp;as &amp;quot;modbus_val*15/65536&amp;quot;.&amp;lt;/span&amp;gt;&lt;br /&gt;
&amp;lt;pre&amp;gt;[Holding Registers]&lt;br /&gt;
numberOfR=3&lt;br /&gt;
R0=0,Vin0,0,15,1,V,0,&amp;quot;modbus_val*15/65536&amp;quot;&lt;br /&gt;
R1=1,Vin1,0,15,1,V,0,&amp;quot;modbus_val*15/65536&amp;quot;&lt;br /&gt;
R2=2,Vin2,0,15,1,V,0,&amp;quot;modbus_val*15/65536&amp;quot;&lt;br /&gt;
&lt;br /&gt;
;tag = offset, name, min, max, precision, unit, data type, lua script&lt;br /&gt;
&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;3.4 Login RMM 3.3 again to check the values that ADAM-4117 and Gateway uploaded, the value is already converted to voltage value.&amp;lt;/span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:larger;&amp;quot;&amp;gt;[[File:Adam-4117-14 modbus 1.0.png|800x600px|Adam-4117-14.png]]&amp;lt;/span&amp;gt;&lt;/div&gt;</summary>
		<author><name>Hank.peng</name></author>	</entry>