− | = <span style="font-size: | + | = Introduction = |
+ | |||
+ | <span style="font-size:large;">Modbus enables communication among many devices connected to the same network, for example, a system that measures temperature and humidity and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.</span> | ||
+ | |||
+ | <span style="font-size:large;">Many of the data types are named from its use in driving relays: a single-bit physical output is called a coil, and a single-bit physical input is called a discrete input or a contact.</span> | ||
+ | |||
+ | <span style="font-size:large;">Modbus Service is a Windows/Linux system service for WISE Agent to read sensor data from Modbus device or write data into Modbus device. After sensor data are acquired, WISE Agent will upload the data to the WISE-PaaS Cloud.</span> | ||
+ | |||
+ | |||
+ | |||
+ | = Modbus Service = | ||
+ | |||
+ | == JSON Format for upload data == | ||
+ | <pre>{ | ||
+ | "Modbus_Handler":{ | ||
+ | "Platform":{ | ||
+ | "bn":"Platform", | ||
+ | "e":[{"n":"Version","sv":"2.0.0"}, | ||
+ | {"n":"Description","sv":"This service is Modbus Service"}, | ||
+ | {"n":"Protocol","sv":"Modbus_TCP"}, | ||
+ | {"n":"Name","sv":"WISE-4012E"}, | ||
+ | {"n":"ClientIP","sv":"127.0.0.1"}, | ||
+ | {"n":"ClientPort","sv":"502"}, | ||
+ | {"n":"Connection","bv":true}] | ||
+ | }, | ||
+ | "Modbus_Device0":{ | ||
+ | "bn":"Modbus_Device0", | ||
+ | "e":[{"n":"UnitID","sv":"1"}], | ||
+ | "Coils":{ | ||
+ | "bn":"Coils", | ||
+ | "e":[{"n":"LED0","bv":true}, | ||
+ | {"n":"LED1","bv":true}, | ||
+ | {"n":"LED2","bv":false}] | ||
+ | } | ||
+ | }, | ||
+ | "Modbus_Device1":{ | ||
+ | "bn":"Modbus_Device1", | ||
+ | "e":[{"n":"UnitID","sv":"2"}], | ||
+ | "Discrete Inputs":{ | ||
+ | "bn":"Discrete Inputs", | ||
+ | "e":[{"n":"Switch0","bv":false}, | ||
+ | {"n":"Switch1","bv":true}, | ||
+ | {"n":"Switch2","bv":false}] | ||
+ | } | ||
+ | } | ||
+ | } | ||
+ | }</pre> | ||
+ | |||
+ | |||
+ | |||
+ | = How To = | ||
+ | |||
+ | == Installation == | ||
+ | |||
+ | <span style="font-size:large;">'''Prerequisited packages''':</span> | ||
+ | |||
+ | <span style="font-size:large;">1. WISE Agent</span> | ||
+ | |||
+ | <span style="font-size:large;"> Please download installer from EdgeSense or DeviceOn portal.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:large;">2. MQTT Broker</span> | ||
+ | |||
+ | <span style="font-size:large;"> You can download installer from this link: [https://mosquitto.org/download/ https://mosquitto.org/download/]</span> | ||
− | |||
− | |||
− | |||
+ | <span style="font-size:large;">'''Modbus Service Setup:'''</span> | ||
+ | <span style="font-size:large;">1. Double click Agent_Modbus_Handler_2.0.x.exe ([http://ess-wiki.advantech.com.tw/view/Modbus_Service#Release Download]) to start installation.</span> | ||
+ | <span style="font-size:large;">2. Click "Next" on the Welcome screen.</span> | ||
+ | <span style="font-size:large;">[[File:Agent modbus handler 02.png|640x480px|Agent modbus handler 02.png]]</span> | ||
− | |||
− | |||
+ | <span style="font-size:large;">3. Select Installation Folder and then click "Next" to continue.</span> | ||
+ | <span style="font-size:large;">[[File:Agent modbus handler 03.png|640x480px|Agent modbus handler 03.png]]</span> | ||
Line 21: | Line 86: | ||
<span style="font-size:large;">4. Click "Install" on the Ready to Install screen to continue.</span> | <span style="font-size:large;">4. Click "Install" on the Ready to Install screen to continue.</span> | ||
− | [[File:Agent modbus handler 04.png| | + | [[File:Agent modbus handler 04.png|640x480px|Agent modbus handler 04.png]] |
Line 27: | Line 92: | ||
<span style="font-size:large;">5. Installation completed, click "Finish" button to exit the Setup Wizard.</span> | <span style="font-size:large;">5. Installation completed, click "Finish" button to exit the Setup Wizard.</span> | ||
− | <span style="font-size:large;">[[File:Agent modbus handler 06.png| | + | <span style="font-size:large;">[[File:Agent modbus handler 06.png|640x480px|Agent modbus handler 06.png]]</span> |
+ | |||
+ | == <span style="font-size:x-large;">Configuration</span> == | ||
+ | |||
+ | === <span style="font-size:large;">Config Modbus Connection</span> === | ||
+ | |||
+ | <span style="font-size:medium;">1. Open File Explorer and change target folder to the Modbus Service installation folder.</span> | ||
+ | |||
+ | <span style="font-size:medium;">2. Open and edit the file Mobus_Handler.ini</span> | ||
+ | |||
+ | <span style="font-size:medium;">2.1 Give a Name for the platform.</span> | ||
+ | |||
+ | <span style="font-size:medium;">2.2 Set the Protocol.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;"><u>Modbus TCP Connection:</u></span> | ||
+ | |||
+ | <span style="font-size:medium;">Protocol=Modbus_TCP</span> | ||
+ | |||
+ | <span style="font-size:medium;">ClientIP=(IP address of Modbus TCP devices)</span> | ||
+ | |||
+ | <span style="font-size:medium;">ClientPort=(Port of Modbus TCP devices) </span> | ||
+ | <span style="font-size:medium;">'''Example:'''</span> | ||
+ | <pre>[Platform] | ||
+ | Name=WISE-4012E | ||
+ | Protocol=Modbus_TCP | ||
+ | ClientIP=127.0.0.1 | ||
+ | ClientPort=502 | ||
+ | Interval=3 | ||
+ | #Interval: The time interval of modbus data access/report cycle in second. | ||
+ | Delay=0 | ||
+ | #Delay: The time delay between two modbus address R/W in millisecond. | ||
+ | #Delay=0 means no delay. | ||
+ | Log=0 | ||
+ | [Devices] | ||
+ | numberOfDevices=2 | ||
+ | Device0=Modbus_Device0.ini | ||
+ | Device1=Modbus_Device1.ini | ||
+ | </pre> | ||
− | |||
− | <span style="font-size: | + | <span style="font-size:medium;"><u>Modbus RTU Connection:</u></span> |
− | <span style="font-size: | + | <span style="font-size:medium;">Protocol=Modbus_RTU</span> |
− | <span style="font-size: | + | <span style="font-size:medium;">SlavePort=(The serial port's device node of the Gateway which connect to Modbus RTU devices)</span> |
− | <span style="font-size: | + | <span style="font-size:medium;">Baud=(The baud rate for the serial port to communicate with Modbus RTU device)</span> |
− | + | <span style="font-size:medium;">Parity=(The parity of the serial port)</span> | |
− | <span style="font-size: | + | <span style="font-size:medium;">DataBits=(The data bits of the serial port) </span> |
− | <span style="font-size: | + | <span style="font-size:medium;">StopBits=(The stop bits of the serial port) </span> |
− | |||
− | |||
− | + | <span style="font-size:medium;">'''Example:'''</span> | |
+ | <pre>[Platform] | ||
+ | Name=EKI-XXXX | ||
+ | Protocol=Modbus_RTU | ||
+ | SlavePort=COM1 | ||
+ | Baud=19200 | ||
+ | Parity=None | ||
+ | DataBits=8 | ||
+ | StopBits=1 | ||
− | + | Interval=3 | |
+ | #Interval: The time interval of modbus data access/report cycle in second. | ||
+ | Delay=0 | ||
+ | #Delay: The time delay between two modbus address R/W in millisecond. | ||
+ | #Delay=0 means no delay. | ||
+ | Log=0 | ||
− | + | [Devices] | |
+ | numberOfDevices=2 | ||
+ | Device0=Modbus_Device0.ini | ||
+ | Device1=Modbus_Device1.ini | ||
+ | </pre> | ||
− | + | <br/> | |
+ | <br/> | ||
− | <span style="font-size:large;">& | + | === <span style="font-size:large;">Config Modbus Devices & Sensors</span> === |
− | <span style="font-size: | + | <span style="font-size: medium;">1. DeviceInfo session:</span> |
− | <span style="font-size: | + | <span style="font-size: medium;"> [DeviceInfo]</span> |
− | <span style="font-size: | + | <span style="font-size:medium;"> UnitId: The UnitID is a device ID for a Modbus TCP device.</span> |
− | + | <span style="font-size:medium;"> SlaveID: The SlaveID is a device ID for a Modbus RTU device.</span> | |
− | |||
+ | <span style="font-size:medium;">2. Coils session</span> | ||
+ | <span style="font-size:medium;"> [Coils]</span> | ||
+ | <span style="font-size:medium;"> NumberOfB: The number of Coils.</span> | ||
− | + | <span style="font-size:medium;"> Bn: The sensors definitation of Coils.</span> | |
− | |||
+ | <span style="font-size:medium;">3. Discrete Inputs session</span> | ||
− | + | <span style="font-size:medium;"> [Discrete Inputs]</span> | |
− | + | <span style="font-size:medium;"> NumberOfIB: The number of Descrete Inputs.</span> | |
− | <span style="font-size: | + | <span style="font-size:medium;"> IBn: The sensors definitation of Descrete Inputs.</span> |
+ | <span style="font-size:medium;">4. Holding Registers session</span> | ||
+ | <span style="font-size:medium;"> [Holding Registers]</span> | ||
+ | <span style="font-size:medium;"> NumberOfR: The number of Holding Registers.</span> | ||
+ | <span style="font-size:medium;"> Rn: The sensors definitation of Holding Registers.</span> | ||
− | |||
− | |||
− | <span style="font-size: | + | <span style="font-size:medium;">5. Input Registers session</span> |
− | <span style="font-size: | + | <span style="font-size:medium;"> [Input Registers]</span> |
+ | <span style="font-size:medium;"> NumbrtOfIR: The number of Input Registers.</span> | ||
+ | <span style="font-size:medium;"> IRn: The sensors definitation of Input Registers.</span> | ||
− | |||
− | === ''' | + | |
+ | <span style="font-size:medium;">6. Coils Block session</span> | ||
+ | |||
+ | <span style="font-size:medium;"> NumberOfBB: The number of Coils Block.</span> | ||
+ | |||
+ | <span style="font-size:medium;"> BBn: The sensors definitation of Coils Block.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">7. Discrete Input Block session</span> | ||
+ | |||
+ | <span style="font-size:medium;"> NumberOfIBB: The number of Descrete Inputs Block.</span> | ||
+ | |||
+ | <span style="font-size:medium;"> IBBn: The sensors definitation of Descrete Inputs Block.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">8. Input Register Block session</span> | ||
+ | |||
+ | <span style="font-size:medium;"> NumbrtOfIRB: The number of Input Registers Block.</span> | ||
+ | |||
+ | <span style="font-size:medium;"> IRBn: The sensors definitation of Input Registers Block.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">9. Holding Register session</span> | ||
+ | |||
+ | <span style="font-size:medium;"> NumberOfRB: The number of Holding Registers Block.</span> | ||
+ | |||
+ | <span style="font-size:medium;"> RBn: The sensors definitation of Holding Registers Block.</span> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | <span style="color:#000000;">'''<span style="font-size:medium;">NOTE! The maximum length of sensor name is 30 characters.</span>'''</span> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">Modbus_Device0.ini Example:</span> | ||
+ | <pre>[DeviceInfo] | ||
+ | # For Modbus_TCP | ||
+ | UnitID=1 | ||
+ | # For Modbus_RTU | ||
+ | #SlaveID=1 | ||
+ | |||
+ | [Coils] | ||
+ | numberOfB=3 | ||
+ | B0=0,LED0 | ||
+ | B1=1,LED1 | ||
+ | B2=2,LED2 | ||
+ | </pre> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">Modbus_Device1.ini Example:</span> | ||
+ | <pre>[DeviceInfo] | ||
+ | # For Modbus_TCP | ||
+ | UnitID=2 | ||
+ | # For Modbus_RTU | ||
+ | #SlaveID=2 | ||
+ | |||
+ | [Discrete Inputs] | ||
+ | numberOfIB=3 | ||
+ | IB0=0,Switch0 | ||
+ | IB1=1,Switch1 | ||
+ | IB2=2,Switch2 | ||
+ | |||
+ | [Input Registers] | ||
+ | numberOfIR=3 | ||
+ | IR0=0,Data0,-1000000,1000000,1,V,0,"" | ||
+ | IR1=1,Data1,-1000000,1000000,1,V,0,"" | ||
+ | IR2=2,Data2,-1000000,1000000,1,V,0,"" | ||
+ | |||
+ | </pre> | ||
+ | |||
+ | <br/> | ||
+ | <br/> | ||
+ | |||
+ | === <span style="font-size:large;">Config Address and Data Types</span> === | ||
+ | |||
+ | <span style="font-size:medium;">The format and sensor address definition of sensors:</span> | ||
+ | |||
+ | <span style="font-size:medium;">1. Single Data Format:</span> | ||
+ | |||
+ | <span style="font-size:medium;">'''Tag = offset, name, min, max, precision, unit, data type, lua script'''</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">2. Block Data Format:</span> | ||
+ | |||
+ | <span style="font-size:medium;">'''Block = offset, length, name'''</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">3. Tag's type, address and offset Mapping</span> | ||
+ | |||
+ | <span style="font-size:medium;">Single Data:</span> | ||
+ | |||
+ | {| border="1" cellspacing="1" cellpadding="1" style="width: 553px;" | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">'''Tag'''</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">'''Type'''</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">'''Address'''</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">'''Offset'''</span> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">B</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Coils</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">00001 ~ 09999</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">IB</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Descrete Inputs</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">10001 ~ 19999</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">IR</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Input Registers</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">30001 ~ 39999</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span><br/> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">R</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Holding Registers</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">40001 ~ 49999</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span><br/> | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">Block Data:</span> | ||
+ | |||
+ | {| border="1" cellspacing="1" cellpadding="1" style="width: 553px;" | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">'''Block'''</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">'''Type'''</span> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">'''Address'''</span> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">'''Offset'''</span> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">BB</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Coils Block</span><br/> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">00001 ~ 09999</span><br/> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">IBB</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Descrete Inputs Block</span><br/> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">10001 ~ 19999</span><br/> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span><br/> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">IRB</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Input Registers Block</span><br/> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">30001 ~ 39999</span><br/> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span><br/> | ||
+ | |- | ||
+ | | style="width: 70px; text-align: center;" | <span style="font-size:medium;">RB</span> | ||
+ | | style="width: 179px;" | <span style="font-size:medium;">Holding Registers Block</span><br/> | ||
+ | | style="width: 145px; text-align: center;" | <span style="font-size:medium;">40001 ~ 49999</span><br/> | ||
+ | | style="width: 141px; text-align: center;" | <span style="font-size:medium;">0~9998</span><br/> | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">4. min and max:</span> | ||
+ | |||
+ | <span style="font-size:medium;"> The minimal and maximal range of the sensor.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">5. Precision:</span> | ||
+ | |||
+ | <span style="font-size:medium;"> The value to denormalize a normalized sensor value become a floating point number.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">6. Unit:</span> | ||
+ | |||
+ | <span style="font-size:medium;"> The unit for the sensor value.</span> | ||
+ | |||
+ | |||
+ | |||
+ | <span style="font-size:medium;">7. The data type definition of sensors:</span> | ||
+ | |||
+ | {| border="1" cellspacing="1" cellpadding="1" style="width: 425px;" | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">'''Data Type'''</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">''' Description'''</span> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">0</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">16-bit operation</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">1</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit float no swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">2</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit float byte and word swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">3</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit float byte swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">4</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit float word swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">5</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit unsigned int no swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">6</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit unsigned int word swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">7</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit signed int no swap</span><br/> | ||
+ | |- | ||
+ | | style="width: 108px; text-align: center;" | <span style="font-size:medium;">8</span> | ||
+ | | style="width: 304px;" | <span style="font-size:medium;">32-bit signed int word swap</span><br/> | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | '''<span style="font-size:medium;">NOTE! For type of "32-bit unsigned int", the maximum support range in 0 ~ 2,147,483,647.</span>''' | ||
+ | |||
+ | == <span style="font-size:x-large;">LUA Conversion</span> == | ||
+ | |||
+ | <span style="font-size:medium;">You can do a simple mathematic operation by add a forms in the LUA conversion string, for example:</span> | ||
+ | |||
+ | Example1: To convert a 16-bit unsigned integer value to 16-bit signed value | ||
+ | <pre>[Holding Registers] | ||
+ | numberOfR=1 | ||
+ | R0=0,Data0,-32768,32767,1,V,0,"(modbus_val>32767) and (modbus_val-65536) or modbus_val" | ||
+ | </pre> | ||
+ | |||
+ | |||
+ | |||
+ | Example2: To do a mathematic forms operation. | ||
+ | <pre>[Holding Registers] | ||
+ | numberOfR=1 | ||
+ | R0=0,Voltage0,0,5,0.001,V,0,"modbus_val*2-10" | ||
+ | </pre> | ||
+ | |||
+ | <span style="color:#FF0000;">'''NOTE: If both precision and LUA string are assigned, LUA string will be calculated with modbus value first, then the new value multiply with assigned precision.'''</span> | ||
+ | |||
+ | |||
+ | |||
+ | LUA functions list:<br/>[https://www.kancloud.cn/thinkphp/lua-guide/43807 https://www.kancloud.cn/thinkphp/lua-guide/43807] | ||
+ | |||
+ | |||
+ | |||
+ | == <span style="font-size:larger;">Docker version</span> == | ||
+ | |||
+ | To config Modbus Service and Restart Service in EdgeSense v1.0.2 Docker version: | ||
<pre>$cd ${Installed path}/Installer/packages/Plugins/docker-edgesense-image-x86/EdgeSense/EService-Modbus/config | <pre>$cd ${Installed path}/Installer/packages/Plugins/docker-edgesense-image-x86/EdgeSense/EService-Modbus/config | ||
$sudo vim Modbus_Handler.ini | $sudo vim Modbus_Handler.ini | ||
− | $sudo docker restart service-modbus</pre> | + | $sudo docker restart service-modbus |
+ | </pre> | ||
+ | |||
+ | |||
+ | |||
+ | = [[Modbus_Handler_2.0_Real_Application_Case|Real Application Case: ADAM-4117]] = | ||
+ | |||
+ | = Release = | ||
+ | |||
+ | <span style="font-size:larger;">This is an overview that displays Modbus Service versions and some stats and numbers for each release.</span> | ||
+ | |||
+ | {| border="1" cellspacing="1" cellpadding="1" style="width: 1065px;" | ||
+ | |- | ||
+ | | style="width: 47px; text-align: center;" | <span style="font-size:larger;">Index</span> | ||
+ | | style="width: 63px; text-align: center;" | <span style="font-size:larger;">Version</span> | ||
+ | | style="width: 72px; text-align: center;" | <span style="font-size:larger;">Date</span> | ||
+ | | style="width: 71px; text-align: center;" | <span style="font-size:larger;">Platform</span> | ||
+ | | style="width: 76px; text-align: center;" | <span style="font-size:larger;">OS</span> | ||
+ | | style="width: 415px; text-align: center;" | <span style="font-size:larger;">Release Note</span> | ||
+ | | style="width: 291px; text-align: center;" | <span style="font-size:larger;">Installer</span> | ||
+ | |- | ||
+ | | style="width: 47px; text-align: center;" | <span style="font-size: 15.6px;">1</span> | ||
+ | | style="width: 63px; text-align: center;" | <span style="font-size:larger;">v2.0.1</span> | ||
+ | | style="width: 72px; text-align: center;" | <span style="font-size:larger;">2018/9/6</span> | ||
+ | | style="width: 71px; text-align: center;" | <span style="font-size:larger;">x86_64 CPU</span><br/> | ||
+ | | style="width: 76px; text-align: center;" | <span style="font-size:larger;">Windows</span><br/> | ||
+ | | style="width: 415px; text-align: center;" | <span style="font-size:larger;">[[Media:Agent_Modbus_Handler_ReleaseNote_2.0.1.txt|Release Note]]</span> | ||
+ | | style="width: 291px; text-align: center;" | | ||
+ | <span style="font-size:larger;"> [file:////eossfs/ESS-Release/EdgeSense/Release/Windows/Modbus_Handler/2.0.1/ Agent_Modbus_Handler_2.0.1.zip]</span> | ||
+ | |||
+ | |- | ||
+ | | style="width: 47px; text-align: center;" | <span style="font-size: 15.6px;">2</span> | ||
+ | | style="width: 63px; text-align: center;" | <span style="font-size:larger;">v2.0.2</span> | ||
+ | | style="width: 72px; text-align: center;" | <span style="font-size:larger;">2020/7/3</span> | ||
+ | | style="width: 71px; text-align: center;" | <span style="font-size:larger;">x86_64 CPU</span><br/> | ||
+ | | style="width: 76px; text-align: center;" | <span style="font-size:larger;">Windows</span><br/> | ||
+ | | style="width: 415px;" | | ||
+ | *<span style="font-size:medium; text-align: left;">Filter out non modbus handler auto report enable request.</span> | ||
+ | |||
+ | | style="width: 291px; text-align: center;" | <span style="font-size:larger;"> [file://eossfs/ESS-Release/EdgeSense/Release/Windows/Modbus_Handler/2.0.2 Agent_Modbus_Handler_2.0.2.zip]</span> | ||
+ | |} | ||
+ | |||
+ | <span style="font-size:larger;">How to download:</span> | ||
+ | <span style="font-size:larger;">Above files are available at local server only, please copy file's url and paste the url in File Explorer to download the file.</span> | ||
+ | <span style="font-size:larger;">1. Right click on Installer file's url and copy file's url.</span> | ||
+ | <span style="font-size:larger;">2. Open File Explorer and paste file's url in File Explorer.</span> | ||
+ | <span style="font-size:larger;">Example:</span> | ||
− | = | + | <span style="font-size:larger;">([[EdgeSense_FAQ|How to access to EOSSFS file server]] )</span> |
Latest revision as of 10:16, 23 December 2021
Contents
Introduction
Modbus enables communication among many devices connected to the same network, for example, a system that measures temperature and humidity and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.
Many of the data types are named from its use in driving relays: a single-bit physical output is called a coil, and a single-bit physical input is called a discrete input or a contact.
Modbus Service is a Windows/Linux system service for WISE Agent to read sensor data from Modbus device or write data into Modbus device. After sensor data are acquired, WISE Agent will upload the data to the WISE-PaaS Cloud.
Modbus Service
JSON Format for upload data
{ "Modbus_Handler":{ "Platform":{ "bn":"Platform", "e":[{"n":"Version","sv":"2.0.0"}, {"n":"Description","sv":"This service is Modbus Service"}, {"n":"Protocol","sv":"Modbus_TCP"}, {"n":"Name","sv":"WISE-4012E"}, {"n":"ClientIP","sv":"127.0.0.1"}, {"n":"ClientPort","sv":"502"}, {"n":"Connection","bv":true}] }, "Modbus_Device0":{ "bn":"Modbus_Device0", "e":[{"n":"UnitID","sv":"1"}], "Coils":{ "bn":"Coils", "e":[{"n":"LED0","bv":true}, {"n":"LED1","bv":true}, {"n":"LED2","bv":false}] } }, "Modbus_Device1":{ "bn":"Modbus_Device1", "e":[{"n":"UnitID","sv":"2"}], "Discrete Inputs":{ "bn":"Discrete Inputs", "e":[{"n":"Switch0","bv":false}, {"n":"Switch1","bv":true}, {"n":"Switch2","bv":false}] } } } }
How To
Installation
Prerequisited packages:
1. WISE Agent
Please download installer from EdgeSense or DeviceOn portal.
2. MQTT Broker
You can download installer from this link: https://mosquitto.org/download/
Modbus Service Setup:
1. Double click Agent_Modbus_Handler_2.0.x.exe (Download) to start installation.
2. Click "Next" on the Welcome screen.
3. Select Installation Folder and then click "Next" to continue.
4. Click "Install" on the Ready to Install screen to continue.
5. Installation completed, click "Finish" button to exit the Setup Wizard.
Configuration
Config Modbus Connection
1. Open File Explorer and change target folder to the Modbus Service installation folder.
2. Open and edit the file Mobus_Handler.ini
2.1 Give a Name for the platform.
2.2 Set the Protocol.
Modbus TCP Connection:
Protocol=Modbus_TCP
ClientIP=(IP address of Modbus TCP devices)
ClientPort=(Port of Modbus TCP devices)
Example:
[Platform] Name=WISE-4012E Protocol=Modbus_TCP ClientIP=127.0.0.1 ClientPort=502 Interval=3 #Interval: The time interval of modbus data access/report cycle in second. Delay=0 #Delay: The time delay between two modbus address R/W in millisecond. #Delay=0 means no delay. Log=0 [Devices] numberOfDevices=2 Device0=Modbus_Device0.ini Device1=Modbus_Device1.ini
Modbus RTU Connection:
Protocol=Modbus_RTU
SlavePort=(The serial port's device node of the Gateway which connect to Modbus RTU devices)
Baud=(The baud rate for the serial port to communicate with Modbus RTU device)
Parity=(The parity of the serial port)
DataBits=(The data bits of the serial port)
StopBits=(The stop bits of the serial port)
Example:
[Platform] Name=EKI-XXXX Protocol=Modbus_RTU SlavePort=COM1 Baud=19200 Parity=None DataBits=8 StopBits=1 Interval=3 #Interval: The time interval of modbus data access/report cycle in second. Delay=0 #Delay: The time delay between two modbus address R/W in millisecond. #Delay=0 means no delay. Log=0 [Devices] numberOfDevices=2 Device0=Modbus_Device0.ini Device1=Modbus_Device1.ini
Config Modbus Devices & Sensors
1. DeviceInfo session:
[DeviceInfo]
UnitId: The UnitID is a device ID for a Modbus TCP device.
SlaveID: The SlaveID is a device ID for a Modbus RTU device.
2. Coils session
[Coils]
NumberOfB: The number of Coils.
Bn: The sensors definitation of Coils.
3. Discrete Inputs session
[Discrete Inputs]
NumberOfIB: The number of Descrete Inputs.
IBn: The sensors definitation of Descrete Inputs.
4. Holding Registers session
[Holding Registers]
NumberOfR: The number of Holding Registers.
Rn: The sensors definitation of Holding Registers.
5. Input Registers session
[Input Registers]
NumbrtOfIR: The number of Input Registers.
IRn: The sensors definitation of Input Registers.
6. Coils Block session
NumberOfBB: The number of Coils Block.
BBn: The sensors definitation of Coils Block.
7. Discrete Input Block session
NumberOfIBB: The number of Descrete Inputs Block.
IBBn: The sensors definitation of Descrete Inputs Block.
8. Input Register Block session
NumbrtOfIRB: The number of Input Registers Block.
IRBn: The sensors definitation of Input Registers Block.
9. Holding Register session
NumberOfRB: The number of Holding Registers Block.
RBn: The sensors definitation of Holding Registers Block.
NOTE! The maximum length of sensor name is 30 characters.
Modbus_Device0.ini Example:
[DeviceInfo] # For Modbus_TCP UnitID=1 # For Modbus_RTU #SlaveID=1 [Coils] numberOfB=3 B0=0,LED0 B1=1,LED1 B2=2,LED2
Modbus_Device1.ini Example:
[DeviceInfo] # For Modbus_TCP UnitID=2 # For Modbus_RTU #SlaveID=2 [Discrete Inputs] numberOfIB=3 IB0=0,Switch0 IB1=1,Switch1 IB2=2,Switch2 [Input Registers] numberOfIR=3 IR0=0,Data0,-1000000,1000000,1,V,0,"" IR1=1,Data1,-1000000,1000000,1,V,0,"" IR2=2,Data2,-1000000,1000000,1,V,0,""
Config Address and Data Types
The format and sensor address definition of sensors:
1. Single Data Format:
Tag = offset, name, min, max, precision, unit, data type, lua script
2. Block Data Format:
Block = offset, length, name
3. Tag's type, address and offset Mapping
Single Data:
Tag | Type | Address | Offset |
B | Coils | 00001 ~ 09999 | 0~9998 |
IB | Descrete Inputs | 10001 ~ 19999 | 0~9998 |
IR | Input Registers | 30001 ~ 39999 | 0~9998 |
R | Holding Registers | 40001 ~ 49999 | 0~9998 |
Block Data:
Block | Type | Address | Offset |
BB | Coils Block |
00001 ~ 09999 |
0~9998 |
IBB | Descrete Inputs Block |
10001 ~ 19999 |
0~9998 |
IRB | Input Registers Block |
30001 ~ 39999 |
0~9998 |
RB | Holding Registers Block |
40001 ~ 49999 |
0~9998 |
4. min and max:
The minimal and maximal range of the sensor.
5. Precision:
The value to denormalize a normalized sensor value become a floating point number.
6. Unit:
The unit for the sensor value.
7. The data type definition of sensors:
Data Type | Description |
0 | 16-bit operation |
1 | 32-bit float no swap |
2 | 32-bit float byte and word swap |
3 | 32-bit float byte swap |
4 | 32-bit float word swap |
5 | 32-bit unsigned int no swap |
6 | 32-bit unsigned int word swap |
7 | 32-bit signed int no swap |
8 | 32-bit signed int word swap |
NOTE! For type of "32-bit unsigned int", the maximum support range in 0 ~ 2,147,483,647.
LUA Conversion
You can do a simple mathematic operation by add a forms in the LUA conversion string, for example:
Example1: To convert a 16-bit unsigned integer value to 16-bit signed value
[Holding Registers] numberOfR=1 R0=0,Data0,-32768,32767,1,V,0,"(modbus_val>32767) and (modbus_val-65536) or modbus_val"
Example2: To do a mathematic forms operation.
[Holding Registers] numberOfR=1 R0=0,Voltage0,0,5,0.001,V,0,"modbus_val*2-10"
NOTE: If both precision and LUA string are assigned, LUA string will be calculated with modbus value first, then the new value multiply with assigned precision.
LUA functions list:
https://www.kancloud.cn/thinkphp/lua-guide/43807
Docker version
To config Modbus Service and Restart Service in EdgeSense v1.0.2 Docker version:
$cd ${Installed path}/Installer/packages/Plugins/docker-edgesense-image-x86/EdgeSense/EService-Modbus/config $sudo vim Modbus_Handler.ini $sudo docker restart service-modbus
Real Application Case: ADAM-4117
Release
This is an overview that displays Modbus Service versions and some stats and numbers for each release.
Index | Version | Date | Platform | OS | Release Note | Installer |
1 | v2.0.1 | 2018/9/6 | x86_64 CPU |
Windows |
Release Note | |
2 | v2.0.2 | 2020/7/3 | x86_64 CPU |
Windows |
|
Agent_Modbus_Handler_2.0.2.zip |
How to download:
Above files are available at local server only, please copy file's url and paste the url in File Explorer to download the file.
1. Right click on Installer file's url and copy file's url.
2. Open File Explorer and paste file's url in File Explorer.
Example: