Difference between revisions of "EPD-660 user guide"
(23 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | = '''EPD- | + | |
− | EPD-660、EPD-662 user guide introduce | + | = '''EPD-660、EPD-662 User Guide''' = |
+ | |||
+ | EPD-660、EPD-662 are 13.3 e-paper display user guide introduce method that device deploy to ePaper Manager server and function list of individual button and behavior of the different lights of led indicator. | ||
== Deploy Setting == | == Deploy Setting == | ||
+ | |||
+ | ePaper Manager server can manager device and issue commands to device so we need device connect to server. Due to there are no interface to configure information of wireless on EPD so we need configure information of wireless on gateway of WISE-32xx series. | ||
+ | |||
+ | EPD device connect to AP of WISE-32xx that SSID and passowrd are ADV-ePape/ePaperePaper so it need check wireless information is match with device. | ||
+ | |||
+ | Basic deploy flow as blow | ||
+ | |||
+ | [[File:EpdDeploy1.jpg|200px|ePaper deploy]] [[File:Wifideploy.JPG|800px|3270 deploy flow2]] | ||
+ | |||
+ | step 1: Configure information on gateway. | ||
+ | |||
+ | User setup the MAC Address of EPD, SSID of AP ,Password of AP ,IP of ePaper Manager Server and Server Port: 5853 on web of WISE-32xx. | ||
+ | |||
+ | [[File:3200dp1.jpg|800px|3270 wifi deploy 1.jpg]] | ||
+ | |||
+ | '''EPD deploy on wise-3200 reference''' [[Wise32xxweb/LuCI#EPD_Deployment|'''WISE-32xx deployment configuration''']] | ||
+ | |||
+ | step 2: EPD device reset to default. | ||
+ | |||
+ | Pressed button 1 keep 8 seconds and green led light, then release button.EPD will connect to WISE-3220 AP after reset to default. | ||
+ | |||
+ | [[File:Pd132b3 3.jpg|500px|wake button]] | ||
+ | |||
+ | step 3: Check device list on ePaper Manager server | ||
+ | |||
+ | [[File:Epd132b3 4.jpg|300px|ePaper]] | ||
+ | |||
+ | Add device to group by MAC address | ||
+ | |||
+ | [[File:Epd132b3 5.jpg|500px|ePaper list]] | ||
== Button == | == Button == | ||
− | + | There are five buttons on EPD panel. Button 1 could wake up or reset system and function of button 2~4 can refresh panel and total page of EPD device has 14 pages and image file have to download from ePaper manager server. | |
− | + | Function from top to the bottom description as below. | |
− | + | [[File:132B3 btn.jpg|500px|system button]] | |
− | + | === Button 1 === | |
− | Button | + | EPD is with battery device so device is always in deep sleep for power saving. Function of Button 1 could wake up from deep sleep and changing device to run mode from deep sleep mode. |
− | + | Button behavior | |
− | + | Wake up:Click button | |
− | + | reset to default: Pressed button keep 8 seconds then button release. | |
− | Button | + | === Button 2 === |
− | + | Refresh image to next page after button click but the bottom of index is 12 and it also pause with 60 seconds when carousel mode is start. | |
− | + | It fast to change the final page by pressed button keep 3 seconds then button release. | |
− | + | For example user download image file to index 1、3、5、7、12, index change to 3 after button click if orginal index is 1. | |
− | Green LED lighting scenario | + | Index change to 12 by button pressed keep 3 seconds then button release if index is 1. |
+ | |||
+ | Button behavior | ||
+ | |||
+ | Forward/carousel mode pause/Alert status stop: Click button | ||
+ | |||
+ | bottom : Pressed button keep 3 seconds then button release | ||
+ | |||
+ | === Button 3 === | ||
+ | |||
+ | Refresh image to previous page after button click but the first of index is 1 and it also pause with 60 seconds when carousel mode is start. It fast to change the first page by pressed button keep 3 seconds then button release. | ||
+ | |||
+ | For example user download image file to index 3、5、7、12, index change to 3 after button click if index is 5. | ||
+ | |||
+ | Index change to 1 by button pressed keep 3 seconds then button release if index is 12. | ||
+ | |||
+ | Button behavior | ||
+ | |||
+ | Backward/carousel mode pause/Alert status stop: Click button | ||
+ | |||
+ | First: Pressed button keep 3 seconds | ||
+ | |||
+ | === Button 4 === | ||
+ | |||
+ | Refresh image to page of 13 after button click on EPD and after 60 seconds, it will return to page in 1~12. | ||
+ | |||
+ | It also pause carousel mode in 60 seconds when carousel mode is start. | ||
+ | |||
+ | Button behavior | ||
+ | |||
+ | Page 13/carousel mode pause/Alert status stop:Click button | ||
+ | |||
+ | === Button 5 === | ||
+ | |||
+ | Refresh image to page of 14 after button click on EPD and after 60 seconds, it will return to page in 1~12. | ||
+ | |||
+ | Function of carousel switch that does work after device accept command from ePaper manager server so user have to make sure send carousel command from server. | ||
+ | |||
+ | It also pause carousel mode in 60 seconds when carousel mode is start. | ||
+ | |||
+ | Button behavior | ||
+ | |||
+ | Page 14/carousel mode pause/Alert status stop:Click button | ||
+ | |||
+ | Cauousel mode switch function: Pressed button 3 second then green led blink. Release button carousel mode is on or off after user have to set up carousel mode variable on ePaper Manager server. | ||
+ | |||
+ | == LED Indicator == | ||
+ | |||
+ | Device has green and red led indicator and description of led behavior as below | ||
+ | |||
+ | [[File:Epd132b3 1.jpg|300px|Green Led]] [[File:Epd132b3 2.jpg|340px|Red Led]] | ||
+ | |||
+ | === Green LED lighting === | ||
+ | |||
+ | scenario | ||
a. Button pressed | a. Button pressed | ||
− | b. Battery charging | + | b. Battery charging(device with battery ): led turn off when batter charge to 100% |
+ | |||
+ | c. DC in (device without battery) | ||
+ | |||
+ | === Green LED blink === | ||
+ | |||
+ | scenario and flow | ||
+ | |||
+ | a. Image Download to flash :Led lighting -> Image Download to flash -> Image Download to flash done -> Led turn off | ||
+ | |||
+ | === Red LED lighting === | ||
+ | |||
+ | scenario and flow | ||
+ | |||
+ | a. Alert command : Accept command from server -> Led lighting -> click button -> Led turn off | ||
+ | |||
+ | === Red LED blink === | ||
+ | |||
+ | a. Battery Error: The battery is unnormal. | ||
+ | |||
+ | == Device mode == | ||
+ | |||
+ | Device has 3 status but device may be in one or two status in the same time. For example device statue can be in charging and carousel mode when plugged the charger. | ||
+ | |||
+ | every mode has own behavior description as below | ||
+ | |||
+ | === Normal mode === | ||
+ | |||
+ | Factory setting is normal mode and routine step as below. | ||
+ | |||
+ | a. device wake up from RTC. | ||
+ | |||
+ | b. Wireless connect Server through Wifi AP and default AP SSID & Password are ADV-ePaper/ePaperePaper | ||
+ | |||
+ | c. Check any command of action from server and report status | ||
+ | |||
+ | d. device go to power saving when it's idle | ||
+ | |||
+ | === Carousel mode === | ||
+ | |||
+ | Device accept command of configuration from ePaper manager server to enter carousel mode and then device refresh image every interval time. | ||
+ | |||
+ | variable of command | ||
+ | |||
+ | a. start page | ||
+ | |||
+ | b. end page | ||
+ | |||
+ | c. interval time in second | ||
+ | |||
+ | === Charging mode === | ||
+ | |||
+ | Device enter charging mode after device wake up from button or RTC clock then plugged the charger and device stop to sleep mode and LED always light. | ||
+ | |||
+ | Note: device could not wake up by plugged charger when device is status in deep sleep unless it wake up from RTC or button but it still can charge battery. | ||
+ | |||
+ | a. DC power in | ||
+ | |||
+ | == Battery status == | ||
+ | |||
+ | === Full battery === | ||
+ | |||
+ | The full battery icon display right bottom when Battery charge over 90% | ||
+ | |||
+ | [[File:EPD 660 Battery full.jpg|300px|EPD 660 low battery icon]] | ||
+ | |||
+ | === Low battery === | ||
+ | |||
+ | The Low battery icon display right bottom when Battery Electricity less 15 % | ||
+ | |||
+ | [[File:Battery low.jpg|300px|EPD 660 low battery icon]] | ||
+ | |||
+ | === Battery error === | ||
+ | |||
+ | The error battery icon display right bottom when battery electricity is too lower and it need adapter offer 9V to charge for 12 hours | ||
+ | |||
+ | [[File:EPD660Battery error.jpg|300px|EPD 660 error battery icon]] | ||
+ | |||
+ | |||
+ | == API function == | ||
+ | |||
+ | API function control behavior of device through ePaper manager server. | ||
+ | |||
+ | it show list of API in this document but operation manual is in ePaper manager server. | ||
+ | |||
+ | 1. [node sync period] range of value is 1~65534 and unit is second | ||
+ | |||
+ | 2. [state report period] range of value is 1~ 65535 and unit is minute | ||
+ | |||
+ | 3. [clear-image-page] range of value is 1~14 | ||
+ | |||
+ | 4. [max-image-page] range of value 1~14 | ||
− | + | 5. [reboot] on/off | |
− | + | 6. [reset to default] on/off | |
− | + | 7. [set alert status] on/off | |
− | + | 8. [set ssid pw] ex. ADV-ePaper, ePaperePaper (ssid,password) | |
− | + | 9. [set carousel mode] ex. 1, 0, 5 ,30 (on or off , start page, end page , interval) | |
− | + | 10. [image update] | |
− | + | 11. [image refresh] |
Latest revision as of 06:45, 26 October 2022
Contents
EPD-660、EPD-662 User Guide
EPD-660、EPD-662 are 13.3 e-paper display user guide introduce method that device deploy to ePaper Manager server and function list of individual button and behavior of the different lights of led indicator.
Deploy Setting
ePaper Manager server can manager device and issue commands to device so we need device connect to server. Due to there are no interface to configure information of wireless on EPD so we need configure information of wireless on gateway of WISE-32xx series.
EPD device connect to AP of WISE-32xx that SSID and passowrd are ADV-ePape/ePaperePaper so it need check wireless information is match with device.
Basic deploy flow as blow
step 1: Configure information on gateway.
User setup the MAC Address of EPD, SSID of AP ,Password of AP ,IP of ePaper Manager Server and Server Port: 5853 on web of WISE-32xx.
EPD deploy on wise-3200 reference WISE-32xx deployment configuration
step 2: EPD device reset to default.
Pressed button 1 keep 8 seconds and green led light, then release button.EPD will connect to WISE-3220 AP after reset to default.
step 3: Check device list on ePaper Manager server
Add device to group by MAC address
Button
There are five buttons on EPD panel. Button 1 could wake up or reset system and function of button 2~4 can refresh panel and total page of EPD device has 14 pages and image file have to download from ePaper manager server.
Function from top to the bottom description as below.
Button 1
EPD is with battery device so device is always in deep sleep for power saving. Function of Button 1 could wake up from deep sleep and changing device to run mode from deep sleep mode.
Button behavior
Wake up:Click button
reset to default: Pressed button keep 8 seconds then button release.
Button 2
Refresh image to next page after button click but the bottom of index is 12 and it also pause with 60 seconds when carousel mode is start.
It fast to change the final page by pressed button keep 3 seconds then button release.
For example user download image file to index 1、3、5、7、12, index change to 3 after button click if orginal index is 1.
Index change to 12 by button pressed keep 3 seconds then button release if index is 1.
Button behavior
Forward/carousel mode pause/Alert status stop: Click button
bottom : Pressed button keep 3 seconds then button release
Button 3
Refresh image to previous page after button click but the first of index is 1 and it also pause with 60 seconds when carousel mode is start. It fast to change the first page by pressed button keep 3 seconds then button release.
For example user download image file to index 3、5、7、12, index change to 3 after button click if index is 5.
Index change to 1 by button pressed keep 3 seconds then button release if index is 12.
Button behavior
Backward/carousel mode pause/Alert status stop: Click button
First: Pressed button keep 3 seconds
Button 4
Refresh image to page of 13 after button click on EPD and after 60 seconds, it will return to page in 1~12.
It also pause carousel mode in 60 seconds when carousel mode is start.
Button behavior
Page 13/carousel mode pause/Alert status stop:Click button
Button 5
Refresh image to page of 14 after button click on EPD and after 60 seconds, it will return to page in 1~12.
Function of carousel switch that does work after device accept command from ePaper manager server so user have to make sure send carousel command from server.
It also pause carousel mode in 60 seconds when carousel mode is start.
Button behavior
Page 14/carousel mode pause/Alert status stop:Click button
Cauousel mode switch function: Pressed button 3 second then green led blink. Release button carousel mode is on or off after user have to set up carousel mode variable on ePaper Manager server.
LED Indicator
Device has green and red led indicator and description of led behavior as below
Green LED lighting
scenario
a. Button pressed
b. Battery charging(device with battery ): led turn off when batter charge to 100%
c. DC in (device without battery)
Green LED blink
scenario and flow
a. Image Download to flash :Led lighting -> Image Download to flash -> Image Download to flash done -> Led turn off
Red LED lighting
scenario and flow
a. Alert command : Accept command from server -> Led lighting -> click button -> Led turn off
Red LED blink
a. Battery Error: The battery is unnormal.
Device mode
Device has 3 status but device may be in one or two status in the same time. For example device statue can be in charging and carousel mode when plugged the charger.
every mode has own behavior description as below
Normal mode
Factory setting is normal mode and routine step as below.
a. device wake up from RTC.
b. Wireless connect Server through Wifi AP and default AP SSID & Password are ADV-ePaper/ePaperePaper
c. Check any command of action from server and report status
d. device go to power saving when it's idle
Carousel mode
Device accept command of configuration from ePaper manager server to enter carousel mode and then device refresh image every interval time.
variable of command
a. start page
b. end page
c. interval time in second
Charging mode
Device enter charging mode after device wake up from button or RTC clock then plugged the charger and device stop to sleep mode and LED always light.
Note: device could not wake up by plugged charger when device is status in deep sleep unless it wake up from RTC or button but it still can charge battery.
a. DC power in
Battery status
Full battery
The full battery icon display right bottom when Battery charge over 90%
Low battery
The Low battery icon display right bottom when Battery Electricity less 15 %
Battery error
The error battery icon display right bottom when battery electricity is too lower and it need adapter offer 9V to charge for 12 hours
API function
API function control behavior of device through ePaper manager server.
it show list of API in this document but operation manual is in ePaper manager server.
1. [node sync period] range of value is 1~65534 and unit is second
2. [state report period] range of value is 1~ 65535 and unit is minute
3. [clear-image-page] range of value is 1~14
4. [max-image-page] range of value 1~14
5. [reboot] on/off
6. [reset to default] on/off
7. [set alert status] on/off
8. [set ssid pw] ex. ADV-ePaper, ePaperePaper (ssid,password)
9. [set carousel mode] ex. 1, 0, 5 ,30 (on or off , start page, end page , interval)
10. [image update]
11. [image refresh]