− | <span style="font-size:xx-large;">'''Installation'''</span> | + | = <span style="font-size:xx-large;">'''Installation'''</span> = |
<span style="font-size:large;">1. Double click Agent_Modbus_Handler_2.0.0.exe to start installation.</span> | <span style="font-size:large;">1. Double click Agent_Modbus_Handler_2.0.0.exe to start installation.</span> | ||
Line 33: | Line 33: | ||
− | <span style="font-size:xx-large;">'''Configuration'''</span> | + | <span style="font-size:xx-large;"></span> |
+ | |||
+ | = <span style="font-size:xx-large;">'''Configuration'''</span> = | ||
<span style="font-size:large;">1. Open File Explorer and change target folder to the Modbus Service installation folder.</span> | <span style="font-size:large;">1. Open File Explorer and change target folder to the Modbus Service installation folder.</span> | ||
Line 93: | Line 95: | ||
− | + | ||
<span style="font-size:large;"> 2.4 Set the content of device detail information.</span> | <span style="font-size:large;"> 2.4 Set the content of device detail information.</span> |
Revision as of 07:35, 17 April 2018
Installation
1. Double click Agent_Modbus_Handler_2.0.0.exe to start installation.
2. Click "Next" on the Welcome screen.
3. Select Installation Folder and then click "Next" to continue.
4. Click "Install" on the Ready to Install screen to continue.
5. Installation completed, click "Finish" button to exit the Setup Wizard.
Configuration
1. Open File Explorer and change target folder to the Modbus Service installation folder.
2. Open and edit the file Mobus_Handler.ini
2.1 Give a Name for the platform.
2.2 Set the Protocol.
For the modbus TCP devices:
Protocol=Modbus_TCP
ClientIP=(IP address of Modbus TCP devices)
ClientPort=(Port of Modbus TCP devices)
Example:
For the modbus RTU devices:
Protocol=Modbus_RTU
SlavePort=(The serial port's device node of the gateway which connect to Modbus RTU devices)
Baud=(The baud rate of the serial port)
Parity=(The parity of the serial port)
DataBits=(The data bits of the serial port)
StopBits=(The stop bits of the serial port)
Example:
2.3 Set the number of modbus devices and device detail information file.
Example:
2.4 Set the content of device detail information.
Example: