Difference between revisions of "EPD-130 application tech"
Line 122: | Line 122: | ||
=== Full update === | === Full update === | ||
− | |||
− | + | x、y start coordinates is given in (0, 0) , width 、height is given in (1600 , 1200). | |
− | |||
− | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 0''' | + | In '''EPD-130B''' panel type. The usually full update command as below. |
+ | |||
+ | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 0''' | ||
'''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 2''' | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 2''' | ||
− | [[File:Epd130 7.jpg|500px|fullupdate]] | + | [[File:Epd130 7.jpg|500px|fullupdate B]] |
− | In '''EPD-130R''' panel type | + | In '''EPD-130R''' panel type. The usually full update command as below. |
− | + | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 0''' | |
− | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 | + | '''IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 1''' |
− | + | [[File:Epd130 8.jpg|500px|full update R]] | |
=== Partial update === | === Partial update === | ||
+ | |||
x, y start coordinate depends on user's defined and the width、height is given in user's define in partial update | x, y start coordinate depends on user's defined and the width、height is given in user's define in partial update | ||
− | Below command is defined start coordinate in (0, 800) and width、height is defined in 1600 , 400. | + | In '''EPD-130B''' panel type. |
+ | |||
+ | Below command is defined start coordinate in (0, 800) and width、height is defined in (1600 , 400). | ||
− | '''IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 0''' | + | '''IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 0''' |
'''IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 2''' | '''IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 2''' | ||
Line 152: | Line 155: | ||
[[File:Epd130 6 2.jpg|500px|partial udate]] | [[File:Epd130 6 2.jpg|500px|partial udate]] | ||
+ | In '''EPD-130R''' panel type | ||
+ | |||
+ | Below command is defined start coordinate in (0, 200) and width、height is defined in (800 , 600). | ||
+ | |||
+ | '''IT8951_USB_Cmd.exe -display -nowait 0 200 800 600 0''' | ||
+ | |||
+ | '''IT8951_USB_Cmd.exe -display -nowait 0 200 800 600 1''' | ||
+ | [[File:Epd130 9.jpg|500px|partial udate]] | ||
'''Note''' The panel resolution is '''1600 x 1200''' | '''Note''' The panel resolution is '''1600 x 1200''' |
Revision as of 12:05, 24 March 2020
Contents
EPD-130 Application guide
This application implement image full/partial update by command line variable. Push image Application is only on Windows platform(Windows 7、Windows 10)。
Components LIST
Item |
Description |
---|---|
1 | 13.3” EPAPER |
2 | EPD-130 PCBA |
3 | cable |
SYSTEM ARCHITECURE
Panel type
- EPD-130R : The panel has black and white color to display picture.
- EPD-130B : The panel has black、white and red color to display picture.
Waveform mode
There are six Waveform mode for image update and short name as below table. This parameter will use in update command parameter.
mode 0 | mode 1 | mode 2 | mode 3 | mode 4 | mode 5 |
INIT | DU | GC16 | GL16 | A2 | DU4 |
INIT(Global update WF) :
- Initialize is used to completely clear the display, if it's left in an unknown state (i.e. if the previous image has been lost by a re-boot)
DU(Local update WF) :
- Direct update Non-flashing waveform that can be used to update. it can update any changed graytone pixel to black or white only.
GC16(Global update WF) :
- Grayscale clear, 16 levels A "flashy" waveform used for 16 level grayscale images. All the pixels are updated or cleared
GL16(Local update WF when white to white , Global update when 16 gray levels) :
- The GL16 waveform is used to update anti-aliased text with reduced flash. GL16 should bed used only with Full Display Update.
- The entire display except pixels staying in white will update as the new image is written. The GL16 waveform has 16 unique gray levels.
A2(Local update WF) :
- animation, 2 Levels is a non-flashing waveform that can be used for fast updates and simple animation.
- This wave form support black & white updates only.
- image quality and ghosting is reduced in exchange for the response time.
DU4(Local update WF) :
- A fast update time(simlar to DU), non-flashy waveform.
- This mode supports transitions from any graytone to graytone 0(Black),5,10.15(White).
- The combination of fast update time and four graytone make it useful for anti-aliased text in menus
Push image application
Hardware and software prepare
Follow steps and picture below to setup the hardware
1. Connected EPD FPC to mainboard
2. Connected micro USB cable to mainboard USB2(CN2) the other side connect to desktop/laptop usb port
3. Download and unzip EPD-132R_CLI_tool
4. Unzip download package and open windows command line
5. Change current directory to user's Adv_CLI_v4 tool directory on command line window
6. User can find IT8951_USB_Cmd.exe application in Adv_CLI_v4
The command parameter in detail as below
Load image
a. Load image >Load selected image file to image buffer. Only supports bmp and jpg type.
IT8951_USB_Cmd.exe -load [file name]
b. Display > Refresh the assigned range of EPD (according to the image buffer and chosen mode)
IT8951_USB_Cmd.exe -display -nowait [x] [y] [width] [height] [mode]
The x, y is the start coordinates and width, height is update range but it can not exceed the resolution. mode see Section 1.3 waveform mode
Full update
x、y start coordinates is given in (0, 0) , width 、height is given in (1600 , 1200).
In EPD-130B panel type. The usually full update command as below.
IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 0
IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 2
In EPD-130R panel type. The usually full update command as below.
IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 0
IT8951_USB_Cmd.exe -display -nowait 0 0 1600 1200 1
Partial update
x, y start coordinate depends on user's defined and the width、height is given in user's define in partial update
In EPD-130B panel type.
Below command is defined start coordinate in (0, 800) and width、height is defined in (1600 , 400).
IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 0
IT8951_USB_Cmd.exe -display -nowait 0 800 1600 400 2
In EPD-130R panel type
Below command is defined start coordinate in (0, 200) and width、height is defined in (800 , 600).
IT8951_USB_Cmd.exe -display -nowait 0 200 800 600 0
IT8951_USB_Cmd.exe -display -nowait 0 200 800 600 1
Note The panel resolution is 1600 x 1200