Difference between revisions of "Modbus Service"

From ESS-WIKI
Jump to: navigation, search
Line 58: Line 58:
  
 
'''<span style="font-size:larger;">Example:</span>'''
 
'''<span style="font-size:larger;">Example:</span>'''
<pre><span style="font-size:larger;">[Platform]
+
<pre>[Platform]
 
Name=WISE-4012E
 
Name=WISE-4012E
 
Protocol=Modbus_TCP
 
Protocol=Modbus_TCP
Line 65: Line 65:
  
 
Interval=3
 
Interval=3
#Interval: The time delay between two modbus access round in second.&nbsp;
+
#Interval: The time delay between two modbus access round in second.;
 
Delay=0
 
Delay=0
 
#Delay: The time delay between two modbus access in millisecond.
 
#Delay: The time delay between two modbus access in millisecond.
 
#Delay=0 means no delay.
 
#Delay=0 means no delay.
 
Log=0
 
Log=0
</span>
+
 
 
</pre>
 
</pre>
  
Line 98: Line 98:
  
 
'''<span style="font-size:larger;">Example:</span>'''
 
'''<span style="font-size:larger;">Example:</span>'''
<pre><span style="font-size:larger;">[Platform]
+
<pre>[Platform]
 
Name=EKI-XXXX
 
Name=EKI-XXXX
 
Protocol=Modbus_RTU
 
Protocol=Modbus_RTU
Line 108: Line 108:
  
 
Interval=3
 
Interval=3
#Interval: The time delay between two modbus access round in second.&nbsp;
+
#Interval: The time delay between two modbus access round in second.;
 
Delay=0
 
Delay=0
 
#Delay: The time delay between two modbus access in millisecond.
 
#Delay: The time delay between two modbus access in millisecond.
 
#Delay=0 means no delay.
 
#Delay=0 means no delay.
 
Log=0
 
Log=0
</span>
+
 
 
</pre>
 
</pre>
  
Line 125: Line 125:
  
 
'''<span style="font-size:larger;">Device0 Example:</span>'''
 
'''<span style="font-size:larger;">Device0 Example:</span>'''
<pre><span style="font-size:larger;">[DeviceInfo]
+
<pre>[DeviceInfo]
 
Name=Modbus_Device0
 
Name=Modbus_Device0
  
Line 138: Line 138:
 
B0=0,LED0
 
B0=0,LED0
 
B1=1,LED1
 
B1=1,LED1
B2=2,LED2</span><span style="font-size:larger;">
+
B2=2,LED2
</span>
 
 
</pre>
 
</pre>
 +
 +
  
  
Line 147: Line 148:
  
 
'''<span style="font-size:larger;">Device1&nbsp;Example:</span>'''
 
'''<span style="font-size:larger;">Device1&nbsp;Example:</span>'''
<pre><span style="font-size:larger;">[DeviceInfo]
+
<pre>[DeviceInfo]
 
Name=Modbus_Device1
 
Name=Modbus_Device1
  
Line 160: Line 161:
 
IB0=0,Switch0
 
IB0=0,Switch0
 
IB1=1,Switch1
 
IB1=1,Switch1
IB2=2,Switch2</span>
+
IB2=2,Switch2</pre>
<span style="font-size:larger;"></span><span style="font-size:larger;">
 
</span></pre>
 
 
 
 
 
 
 
 
 
  
 
= EdgeSense Linux Docker version =
 
= EdgeSense Linux Docker version =

Revision as of 07:20, 7 May 2018

Installation

1. Double click Agent_Modbus_Handler_2.0.0.exe to start installation.

2. Click "Next" on the Welcome screen.

Agent modbus handler 02.png



3. Select Installation Folder and then click "Next" to continue.

Agent modbus handler 03.png



4. Click "Install" on the Ready to Install screen to continue.

Agent modbus handler 04.png


5. Installation completed, click "Finish" button to exit the Setup Wizard.

Agent modbus handler 06.png





Configuration

1. Open File Explorer and change target folder to the Modbus Service installation folder.

2. Open and edit the file Mobus_Handler.ini

2.1 Give a Name for the platform.

2.2 Set the Protocol.

For the modbus TCP devices:

Protocol=Modbus_TCP

ClientIP=(IP address of Modbus TCP devices)

ClientPort=(Port of Modbus TCP devices)

        

Example:

[Platform]
Name=WISE-4012E
Protocol=Modbus_TCP
ClientIP=127.0.0.1
ClientPort=502

Interval=3
#Interval: The time delay between two modbus access round in second.;
Delay=0
#Delay: The time delay between two modbus access in millisecond.
#Delay=0 means no delay.
Log=0




For the modbus RTU devices:

Protocol=Modbus_RTU

SlavePort=(The serial port's device node of the gateway which connect to Modbus RTU devices)

Baud=(The baud rate of the serial port)

Parity=(The parity of the serial port)

DataBits=(The data bits of the serial port)              

StopBits=(The stop bits of the serial port) 



Example:

[Platform]
Name=EKI-XXXX
Protocol=Modbus_RTU
SlavePort=COM1
Baud=19200
Parity=None
DataBits=8
StopBits=1

Interval=3
#Interval: The time delay between two modbus access round in second.;
Delay=0
#Delay: The time delay between two modbus access in millisecond.
#Delay=0 means no delay.
Log=0




2.3 Set the number of modbus devices and device detail information file.

Device0 Example:

[DeviceInfo]
Name=Modbus_Device0

# For Modbus_TCP
UnitID=1

# For Modbus_RTU
#SlaveID=1

[Coils]
numberOfB=3
B0=0,LED0
B1=1,LED1
B2=2,LED2




Device1 Example:

[DeviceInfo]
Name=Modbus_Device1

# For Modbus_TCP
UnitID=2

# For Modbus_RTU
#SlaveID=2

[Discrete Inputs]
numberOfIB=3
IB0=0,Switch0
IB1=1,Switch1
IB2=2,Switch2

EdgeSense Linux Docker version

How to config Modbus Service and Restart Service

$cd ${Installed path}/Installer/packages/Plugins/docker-edgesense-image-x86/EdgeSense/EService-Modbus/config
$sudo vim Modbus_Handler.ini
$sudo docker restart service-modbus




JSON Format for upload data

{
   "Modbus_Handler":{
      "Platform":{
         "bn":"Platform",
         "e":[{"n":"Version","sv":"2.0.0"},
              {"n":"Description","sv":"This service is Modbus Service"},
              {"n":"Protocol","sv":"Modbus_TCP"},
              {"n":"Name","sv":"WISE-4012E"},
              {"n":"ClientIP","sv":"127.0.0.1"},
              {"n":"ClientPort","sv":"502"},
              {"n":"Connection","bv":true}]
      },
      "Modbus_Device0":{
         "bn":"Modbus_Device0",
         "e":[{"n":"UnitID","sv":"1"}],
         "Coils":{
            "bn":"Coils",
            "e":[{"n":"LED0","bv":true},
                 {"n":"LED1","bv":true},
                 {"n":"LED2","bv":false}]
         }
      },
      "Modbus_Device1":{
         "bn":"Modbus_Device1",
         "e":[{"n":"UnitID","sv":"2"}],
         "Discrete Inputs":{
            "bn":"Discrete Inputs",
            "e":[{"n":"Switch0","bv":false},
                 {"n":"Switch1","bv":true},
                 {"n":"Switch2","bv":false}]
         }
      }
   }
}