Difference between revisions of "Modbus Master"

From ESS-WIKI
Jump to: navigation, search
Line 61: Line 61:
 
<span style="font-size:medium;">EdgeSense Modbus Master can manage multiple Modbus Slave setting and individual sensor's parameters, below settings are default after Modbus Master installation.</span>
 
<span style="font-size:medium;">EdgeSense Modbus Master can manage multiple Modbus Slave setting and individual sensor's parameters, below settings are default after Modbus Master installation.</span>
  
<span style="font-size:medium;"></span>
+
<br/>
  
<span style="font-size:medium;">1. Device Configuration: device-industry.yaml</span>
+
<span style="font-size:medium;">1. Device Configuration: <Install_folder>\config\industry\device-industry.yaml</span>
  
 +
<br/>
  
 
<pre>metadata:  
 
<pre>metadata:  

Revision as of 08:13, 10 January 2020

Introduction

Modbus enables communication among many devices connected to the same network, for example, a system that measures temperature and humidity and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.

Many of the data types are named from its use in driving relays: a single-bit physical output is called a coil, and a single-bit physical input is called a discrete input or a contact.

Modbus Service is a Windows/Linux system service for WISE Agent to read sensor data from Modbus device or write data into Modbus device. After sensor data are acquired, WISE Agent will upload the data to the WISE-PaaS Cloud.





Features

EdgeSense Modbus-Master aims to collect data from Modbus Slave.

Feature:

  • Support connection with multiple Modbus slave.
  • Support Modbus TCP and Modbus RTU.
  • Support individual sensor upload interval.
  • Configurable sensor alias.
  • Support byte swap.
  • Currently support up-link Modbus data to WISE-PaaS , not support down-link from WISE-PaaS.


How to

Software Requirements

  • MQTT broker
  • Node.js


Installation

Windows:

1. Download Modbus-Master for Windows from Release Table.

2. Double click the installer to launch the installer to install it to the machine.


Linux:

N.A.



Configuration

EdgeSense Modbus Master can manage multiple Modbus Slave setting and individual sensor's parameters, below settings are default after Modbus Master installation.


1. Device Configuration: <Install_folder>\config\industry\device-industry.yaml


metadata: 
  name: "Modbus devices"
  labels: ["Modbus"] 
  Description: "Modbus TCP/RTU devices with 3 sensors in holding register area 40001~40003"
  UpdateData: 2020-01-08-14:25:30

# DeviceInfo: You can add a new device with unique name
 # <DeviceName>: Unique Device Name
   # Params:

LinkInfo: 
  COM1:
    Params:
      Driver: Modbus-RTU
      ConnectType: Serial
      PortName: COM1
      BaudRate: 9600
      DataBits: 8
      StopBits: 1
      Parity: None
    
    Info: 
      PollingInterval: 1000  # Polling interval ( milliseconds )
      Timeout: 100           # A request timeout ( milliseconds )
      Retry: 3               # Retries min:0 max:3 ( count )
      AliveTime: 60          # Link Timeout in second: SDK will release this link if there are any request over this AliveTime ( second )
      CheckLinkInterval: 5   # Check link status interval (second)

    DevList: 
      - Device-1

  TCP-IP-1:
     Params: 
       Driver: Modbus-TCP
       ConnectType: Net
       IP: 127.0.0.1
       Port: 502
   
     Info: 
      PollingInterval: 1000  # Polling interval in milliseconds
      Timeout: 100           # A request timeout in milliseconds
      Retry: 3               # Count of retry min:0 max:3   
      AliveTime: 60          # Link Timeout in second: SDK will release this link if there are any request over this AliveTime ( second )
      CheckLinkInterval: 5   # Check link status interval (second)

     DevList:
      - Device-2


DeviceInfo:
 Device-1: 
  Params: 
    Station: 1

  Profile: MODBUS_DEVICE_01.yaml

 Device-2:
  Params:
    Station: 2

  Profile: MODBUS_DEVICE_02.yaml


Demonstration