Difference between revisions of "Modbus Service"
(2 intermediate revisions by the same user not shown) | |||
Line 523: | Line 523: | ||
| style="width: 76px; text-align: center;" | <span style="font-size:larger;">Windows</span><br/> | | style="width: 76px; text-align: center;" | <span style="font-size:larger;">Windows</span><br/> | ||
| style="width: 415px;" | | | style="width: 415px;" | | ||
− | *<span style="font-size:medium; text-align: left;"> | + | *<span style="font-size:medium; text-align: left;">Filter out non modbus handler auto report enable request.</span> |
| style="width: 291px; text-align: center;" | <span style="font-size:larger;"> [file://eossfs/ESS-Release/EdgeSense/Release/Windows/Modbus_Handler/2.0.2 Agent_Modbus_Handler_2.0.2.zip]</span> | | style="width: 291px; text-align: center;" | <span style="font-size:larger;"> [file://eossfs/ESS-Release/EdgeSense/Release/Windows/Modbus_Handler/2.0.2 Agent_Modbus_Handler_2.0.2.zip]</span> | ||
|} | |} | ||
− | <span style="font-size:larger;">Above files are available at local server, please paste file's url | + | <span style="font-size:larger;">How to download:</span> |
+ | |||
+ | <span style="font-size:larger;">Above files are available at local server only, please copy file's url and paste the url in File Explorer to download the file.</span> | ||
+ | |||
+ | <span style="font-size:larger;">1. Right click on Installer file's url and copy file's url.</span> | ||
+ | |||
+ | <span style="font-size:larger;">2. Open File Explorer and paste file's url in File Explorer.</span> | ||
+ | |||
+ | <span style="font-size:larger;">Example:</span> | ||
+ | |||
+ | <span style="font-size:larger;">([[EdgeSense_FAQ|How to access to EOSSFS file server]] )</span> |
Latest revision as of 10:16, 23 December 2021
Contents
Introduction
Modbus enables communication among many devices connected to the same network, for example, a system that measures temperature and humidity and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.
Many of the data types are named from its use in driving relays: a single-bit physical output is called a coil, and a single-bit physical input is called a discrete input or a contact.
Modbus Service is a Windows/Linux system service for WISE Agent to read sensor data from Modbus device or write data into Modbus device. After sensor data are acquired, WISE Agent will upload the data to the WISE-PaaS Cloud.
Modbus Service
JSON Format for upload data
{ "Modbus_Handler":{ "Platform":{ "bn":"Platform", "e":[{"n":"Version","sv":"2.0.0"}, {"n":"Description","sv":"This service is Modbus Service"}, {"n":"Protocol","sv":"Modbus_TCP"}, {"n":"Name","sv":"WISE-4012E"}, {"n":"ClientIP","sv":"127.0.0.1"}, {"n":"ClientPort","sv":"502"}, {"n":"Connection","bv":true}] }, "Modbus_Device0":{ "bn":"Modbus_Device0", "e":[{"n":"UnitID","sv":"1"}], "Coils":{ "bn":"Coils", "e":[{"n":"LED0","bv":true}, {"n":"LED1","bv":true}, {"n":"LED2","bv":false}] } }, "Modbus_Device1":{ "bn":"Modbus_Device1", "e":[{"n":"UnitID","sv":"2"}], "Discrete Inputs":{ "bn":"Discrete Inputs", "e":[{"n":"Switch0","bv":false}, {"n":"Switch1","bv":true}, {"n":"Switch2","bv":false}] } } } }
How To
Installation
Prerequisited packages:
1. WISE Agent
Please download installer from EdgeSense or DeviceOn portal.
2. MQTT Broker
You can download installer from this link: https://mosquitto.org/download/
Modbus Service Setup:
1. Double click Agent_Modbus_Handler_2.0.x.exe (Download) to start installation.
2. Click "Next" on the Welcome screen.
3. Select Installation Folder and then click "Next" to continue.
4. Click "Install" on the Ready to Install screen to continue.
5. Installation completed, click "Finish" button to exit the Setup Wizard.
Configuration
Config Modbus Connection
1. Open File Explorer and change target folder to the Modbus Service installation folder.
2. Open and edit the file Mobus_Handler.ini
2.1 Give a Name for the platform.
2.2 Set the Protocol.
Modbus TCP Connection:
Protocol=Modbus_TCP
ClientIP=(IP address of Modbus TCP devices)
ClientPort=(Port of Modbus TCP devices)
Example:
[Platform] Name=WISE-4012E Protocol=Modbus_TCP ClientIP=127.0.0.1 ClientPort=502 Interval=3 #Interval: The time interval of modbus data access/report cycle in second. Delay=0 #Delay: The time delay between two modbus address R/W in millisecond. #Delay=0 means no delay. Log=0 [Devices] numberOfDevices=2 Device0=Modbus_Device0.ini Device1=Modbus_Device1.ini
Modbus RTU Connection:
Protocol=Modbus_RTU
SlavePort=(The serial port's device node of the Gateway which connect to Modbus RTU devices)
Baud=(The baud rate for the serial port to communicate with Modbus RTU device)
Parity=(The parity of the serial port)
DataBits=(The data bits of the serial port)
StopBits=(The stop bits of the serial port)
Example:
[Platform] Name=EKI-XXXX Protocol=Modbus_RTU SlavePort=COM1 Baud=19200 Parity=None DataBits=8 StopBits=1 Interval=3 #Interval: The time interval of modbus data access/report cycle in second. Delay=0 #Delay: The time delay between two modbus address R/W in millisecond. #Delay=0 means no delay. Log=0 [Devices] numberOfDevices=2 Device0=Modbus_Device0.ini Device1=Modbus_Device1.ini
Config Modbus Devices & Sensors
1. DeviceInfo session:
[DeviceInfo]
UnitId: The UnitID is a device ID for a Modbus TCP device.
SlaveID: The SlaveID is a device ID for a Modbus RTU device.
2. Coils session
[Coils]
NumberOfB: The number of Coils.
Bn: The sensors definitation of Coils.
3. Discrete Inputs session
[Discrete Inputs]
NumberOfIB: The number of Descrete Inputs.
IBn: The sensors definitation of Descrete Inputs.
4. Holding Registers session
[Holding Registers]
NumberOfR: The number of Holding Registers.
Rn: The sensors definitation of Holding Registers.
5. Input Registers session
[Input Registers]
NumbrtOfIR: The number of Input Registers.
IRn: The sensors definitation of Input Registers.
6. Coils Block session
NumberOfBB: The number of Coils Block.
BBn: The sensors definitation of Coils Block.
7. Discrete Input Block session
NumberOfIBB: The number of Descrete Inputs Block.
IBBn: The sensors definitation of Descrete Inputs Block.
8. Input Register Block session
NumbrtOfIRB: The number of Input Registers Block.
IRBn: The sensors definitation of Input Registers Block.
9. Holding Register session
NumberOfRB: The number of Holding Registers Block.
RBn: The sensors definitation of Holding Registers Block.
NOTE! The maximum length of sensor name is 30 characters.
Modbus_Device0.ini Example:
[DeviceInfo] # For Modbus_TCP UnitID=1 # For Modbus_RTU #SlaveID=1 [Coils] numberOfB=3 B0=0,LED0 B1=1,LED1 B2=2,LED2
Modbus_Device1.ini Example:
[DeviceInfo] # For Modbus_TCP UnitID=2 # For Modbus_RTU #SlaveID=2 [Discrete Inputs] numberOfIB=3 IB0=0,Switch0 IB1=1,Switch1 IB2=2,Switch2 [Input Registers] numberOfIR=3 IR0=0,Data0,-1000000,1000000,1,V,0,"" IR1=1,Data1,-1000000,1000000,1,V,0,"" IR2=2,Data2,-1000000,1000000,1,V,0,""
Config Address and Data Types
The format and sensor address definition of sensors:
1. Single Data Format:
Tag = offset, name, min, max, precision, unit, data type, lua script
2. Block Data Format:
Block = offset, length, name
3. Tag's type, address and offset Mapping
Single Data:
Tag | Type | Address | Offset |
B | Coils | 00001 ~ 09999 | 0~9998 |
IB | Descrete Inputs | 10001 ~ 19999 | 0~9998 |
IR | Input Registers | 30001 ~ 39999 | 0~9998 |
R | Holding Registers | 40001 ~ 49999 | 0~9998 |
Block Data:
Block | Type | Address | Offset |
BB | Coils Block |
00001 ~ 09999 |
0~9998 |
IBB | Descrete Inputs Block |
10001 ~ 19999 |
0~9998 |
IRB | Input Registers Block |
30001 ~ 39999 |
0~9998 |
RB | Holding Registers Block |
40001 ~ 49999 |
0~9998 |
4. min and max:
The minimal and maximal range of the sensor.
5. Precision:
The value to denormalize a normalized sensor value become a floating point number.
6. Unit:
The unit for the sensor value.
7. The data type definition of sensors:
Data Type | Description |
0 | 16-bit operation |
1 | 32-bit float no swap |
2 | 32-bit float byte and word swap |
3 | 32-bit float byte swap |
4 | 32-bit float word swap |
5 | 32-bit unsigned int no swap |
6 | 32-bit unsigned int word swap |
7 | 32-bit signed int no swap |
8 | 32-bit signed int word swap |
NOTE! For type of "32-bit unsigned int", the maximum support range in 0 ~ 2,147,483,647.
LUA Conversion
You can do a simple mathematic operation by add a forms in the LUA conversion string, for example:
Example1: To convert a 16-bit unsigned integer value to 16-bit signed value
[Holding Registers] numberOfR=1 R0=0,Data0,-32768,32767,1,V,0,"(modbus_val>32767) and (modbus_val-65536) or modbus_val"
Example2: To do a mathematic forms operation.
[Holding Registers] numberOfR=1 R0=0,Voltage0,0,5,0.001,V,0,"modbus_val*2-10"
NOTE: If both precision and LUA string are assigned, LUA string will be calculated with modbus value first, then the new value multiply with assigned precision.
LUA functions list:
https://www.kancloud.cn/thinkphp/lua-guide/43807
Docker version
To config Modbus Service and Restart Service in EdgeSense v1.0.2 Docker version:
$cd ${Installed path}/Installer/packages/Plugins/docker-edgesense-image-x86/EdgeSense/EService-Modbus/config $sudo vim Modbus_Handler.ini $sudo docker restart service-modbus
Real Application Case: ADAM-4117
Release
This is an overview that displays Modbus Service versions and some stats and numbers for each release.
Index | Version | Date | Platform | OS | Release Note | Installer |
1 | v2.0.1 | 2018/9/6 | x86_64 CPU |
Windows |
Release Note | |
2 | v2.0.2 | 2020/7/3 | x86_64 CPU |
Windows |
|
Agent_Modbus_Handler_2.0.2.zip |
How to download:
Above files are available at local server only, please copy file's url and paste the url in File Explorer to download the file.
1. Right click on Installer file's url and copy file's url.
2. Open File Explorer and paste file's url in File Explorer.
Example: