==Get SenHub Info== | ==Get SenHub Info== | ||
===Get SenHub Device info=== | ===Get SenHub Device info=== | ||
+ | '''Request''' | ||
+ | GET /dev/info?action=list | ||
+ | Direction: GW -> SenHub | ||
+ | TP: GET | ||
+ | Type:0 | ||
+ | Code:1 | ||
+ | PAYLOAD: /dev/info?action=list | ||
+ | |||
+ | '''Response''' | ||
+ | Direction: SenHub-> GW | ||
+ | TP : Content | ||
+ | Type:2 | ||
+ | Code:69 | ||
+ | PAYLOAD: </dev>;n="Room1", mdl="WISE1020", sw="1.0.01", reset=0 | ||
+ | |||
===Get SenHub Net info=== | ===Get SenHub Net info=== | ||
==Get Sensor Info== | ==Get Sensor Info== |
Revision as of 04:16, 11 March 2016
Contents
Advantech CoAP-like Packet Structure
Header Size: 8 Bytes
Payload Size: 0 ~ 70 (Max) Bytes
Name | Size ( bits ) |
---|---|
Ver | 2 |
Type (T) | 2 |
TKL: Token Length | 4 |
Code | 8 |
Message ID | 16 |
Length | 32 |
Type (T) : 2-bit unsigned integer Transaction Type field. Indicates if this message is
- Confirmable (0): Some messages require an acknowledgment
- Non-Confirmable (1): Some other messages do not require an acknowledgment
- Acknowledgment (2): An Acknowledgment message acknowledges that a specific Confirmable message (identified by its Transaction ID) arrived
- Reset (3): A Reset message indicates that a specific Confirmable message was received, but some context is missing to properly process it. This condition is usually caused when
- the receiving node has rebooted and has forgotten some state that would be required to interpret the message
Code : : 8-bit unsigned integer
Request
- GET(0.01): 1
- PUT(0.03): 3
Response
- Change(2.04): 68
- Content(2.05): 69
- Bad Request(4.00): 128
- Unauthorized(4.01): 129
- Not Found(4.04): 132
- Method Not Allowed(4.05): 133
- Not Implemented(5.01): 161
IPSO for CoAP-like
IPSO RESTful API Rule: /{Object ID}/{Object Instance}/{Resource ID}/
IPSO Smart Object ID
Sensor | Object ID |
---|---|
Temperature | 3303 |
Humidity | 3304 |
Magnetic | 3314 |
Accelerometer | 3313 |
Light Sensor | 3301 |
Digital Output | 3201 |
Digital Input | 3200 |
CO2 | 9001 |
CO | 9002 |
Ultrasonic | 9200 |
IPSO Smart Resource ID
Resource | Object ID |
---|---|
DI Status | 5500 |
DO Status | 5550 |
Min Range Value | 5603 |
Max Range Value | 5604 |
Sensor Value | 5700 |
Sensor Units | 5701 |
X Value | 5702 |
Y Value | 5703 |
Z Value | 5704 |
Compass Direction | 5705 |
CoAP-like Command
URI Resources | Description |
---|---|
/dev/info | Information of Sensor Hub |
/net/info | Information of Net Communication |
/net/status | Status of Network |
/sen/info | Information of Sensor |
/sen/status | Status of Sensors |
Commands (Key) | Value | Description | For URI Resources | Example |
---|---|---|---|---|
action | list | List detail information | /sen/info, /dev/info, /net/info | GET /sen/info?action=list |
action | observe | Observe status | /sen/status, /net/status | GET /sen/status?action=observe&id=all |
action | cancel | Cancel observe | /sen/status, /net/status | GET /sen/status?action=cancel&id=all |
field | id | List all sensor id | /sen/info | GET /sen/info?action=list&field=id |
field | health | Network health status | /net/status | GET /net/status?field=health |
id | all | Get all sensor’s data | /sen/info, /sen/status | GET /sen/status?action=observe&id=all |
id | 0,1,2,3... | Get one of sensor data | /sen/info, /sen/status | GET /sen/status?action=observe&id=0,1 |
CoAP-like Protocols
Get SenHub Info
Get SenHub Device info
Request GET /dev/info?action=list Direction: GW -> SenHub TP: GET Type:0 Code:1 PAYLOAD: /dev/info?action=list
Response Direction: SenHub-> GW TP : Content Type:2 Code:69 PAYLOAD: </dev>;n="Room1", mdl="WISE1020", sw="1.0.01", reset=0