Difference between revisions of "AlarmEvent"

From ESS-WIKI
Jump to: navigation, search
Line 29: Line 29:
  
 
<span style="font-size:medium;">'''event_config.json (location: C:\Program Files (x86)\Advantech\AlarmEvent\config)'''</span>
 
<span style="font-size:medium;">'''event_config.json (location: C:\Program Files (x86)\Advantech\AlarmEvent\config)'''</span>
 +
 +
*handler_name: Subcribe handler name
 +
*tag_name:&nbsp;Subcribe tag name
 +
*subtype: Event subtype
 +
*event:
 +
*#severity&nbsp;:&nbsp;<pre>Emergency = 0
 +
                            Warning  = 4</pre>
 
<pre>{
 
<pre>{
 
     "handler_name":"Modbus_Handler",   
 
     "handler_name":"Modbus_Handler",   

Revision as of 05:06, 23 November 2018

Introduction

Alarm Event

AlarmEvent Architecture.jpg

How to

Software Requirements

  • MQTT broker  V1.0.3
  • EI Agent
  • Agent_Modbus_Handler_2.0.1-rc2

Installation

1.Double click AlarmEvent-X.X.X.exe to install.

2.Click "Next" to continue the setup wizard.

3.Select installation folder then click "Next"

4.Click "Next" to begin the installation

5.Complete the installation, click "Finish" to exit the setup wizard

6.Start service "alarmevent.exe"

Configuration​

event_config.json (location: C:\Program Files (x86)\Advantech\AlarmEvent\config)

  • handler_name: Subcribe handler name
  • tag_name: Subcribe tag name
  • subtype: Event subtype
  • event:
    1. severity : 
      Emergency = 0 
Warning = 4
{
    "handler_name":"Modbus_Handler",   
    "tag_name":"Error_Code",
    "subtype":"TC_AC",

    "event":
    {
        "1": {"severity":0, "msg_code":241, "msg":"Door Open","error_code": "E:0030", "extmsg":"Immediate stop: Enclosure door open"},
        "2": {"severity":4, "msg_code":242, "msg":"Door Open", "error_code": "A:0030","extmsg":"Warning: Enclosure door open"},
        "3": {"severity":4, "msg_code":250, "msg":"CAB FTR DP ALM","error_code": "A:0031", "extmsg":"Warning: Cabinet filter differential pressure"},
        "4": {"severity":0, "msg_code":321, "msg":"Oil level","error_code": "E:0040", "extmsg":"Immediate stop: Oil level alarm"},
        "5": {"severity":4, "msg_code":322, "msg":"Oil level alarm","error_code": "A:0040", "extmsg":"Warning: Oil level high"},
        "6": {"severity":0, "msg_code":401, "msg":"RD alarm","error_code": "E:0050", "extmsg":"Immediate stop: Refrigerant dryer"},
        "7": {"severity":4, "msg_code":402, "msg":"RD alarm","error_code": "A:0050", "extmsg":"Warning: Refrigerant dryer"},
        "8": {"severity":0, "msg_code":481, "msg":"Belt drive SERV","error_code": "E:0060", "extmsg":"Immediate stop: Belt drive service"},
        "9": {"severity":0, "msg_code":561, "msg":"Fan MTR IMM stop","error_code": "E:0070", "extmsg":"Immediate stop: Fan motor trip"}
    },       

    "server":"127.0.0.1",
    "server_port": 3000
}

Json Data Format

Use Case

Release