Difference between revisions of "UIO-4033 DO1-8/DI1-8"

From ESS-WIKI
Jump to: navigation, search
(Set and Get DO Status)
Line 55: Line 55:
  
 
   3-10V is unstable status.
 
   3-10V is unstable status.
 +
  
 
=== '''Set and Get DO Status''' ===
 
=== '''Set and Get DO Status''' ===
  
Take DO1 for example:
+
Take DO1 for example:(The DO interface of UIO-4033 is of sink type)
 
<pre># #---- Set 0 to DO1 ----# #
 
<pre># #---- Set 0 to DO1 ----# #
 
# echo 0 > /dev/DO1
 
# echo 0 > /dev/DO1
Line 69: Line 70:
 
1
 
1
 
</pre>
 
</pre>
 +
 +
The wiring and measurement methods can be referred to as shown in the following diagram.
 +
 +
[[File:UIO-4033-DO.png]]

Revision as of 10:33, 18 July 2025

UIO-4033 & UIO-4035 both have eight DI ports and eight DO ports.
UIO-4033 DO1-4.png

RTENOTITLE

UIO-4033 DO5-8.png

RTENOTITLE

UIO-4033 DI1-4.png

RTENOTITLE

UIO-4033 DI5-8.png

RTENOTITLE

Show DI/DO Ports

List DI/DO supported ports:

Show DI/DO Ports

# #---- Show DI ports ----# #
# cd /dev/
# ls DI*
DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8

# #---- Show DO ports ----# #
# cd /dev/
# ls DO*
DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8

Get DI Status

Take DI1 for example

# cat /dev/DI1
1

Note:

1. DI ports have two types: Dry or Wet.

2. For Dry ports

    0 means the external circuit is conductive.

    1 means the external circuit is NOT conductive.

3. For Wet ports

    0 means the voltage of input is between 10-30V

   1 means the voltage of input is between 0-3V

   3-10V is unstable status.


Set and Get DO Status

Take DO1 for example:(The DO interface of UIO-4033 is of sink type)

# #---- Set 0 to DO1 ----# #
# echo 0 > /dev/DO1

# #---- Set 1 to DO1 ----# #
# echo 1 > /dev/DO1

# #---- Get DO1 status ----# #
# cat /dev/DO1
1

The wiring and measurement methods can be referred to as shown in the following diagram.

UIO-4033-DO.png