2. Enable Modbus Plugin with below settings for the demonstrations:
 
2. Enable Modbus Plugin with below settings for the demonstrations:
  
[Platform]
+
'''[Platform]'''
  
Name=WISE-4012E
+
'''Name=WISE-4012E'''
  
Protocol=Modbus_TCP
+
'''Protocol=Modbus_TCP'''
  
ClientIP=127.0.0.1
+
'''ClientIP=127.0.0.1'''
  
ClientPort=502
+
'''ClientPort=502'''
  
UnitID=1
+
'''UnitID=1'''
  
Interval=1
+
'''Interval=1'''
  
#Interval: The time delay between two modbus access round in second.
+
'''#Interval: The time delay between two modbus access round in second.'''
  
Delay=0
+
'''Delay=0'''
  
#Delay: The time delay between two modbus access in millisecond.
+
'''#Delay: The time delay between two modbus access in millisecond.'''
  
#Delay=0 means no delay.
+
'''#Delay=0 means no delay.'''
  
Log=0
+
'''Log=0'''
  
 +
 
  
 +
'''[Holding Registers]'''
  
[Holding Registers]
+
'''numberOfR=3'''
  
numberOfR=3
+
'''R0=0,Data0,-1000000,1000000,1,V,0,""'''
  
R0=0,Data0,-1000000,1000000,1,V,0,""
+
'''R1=1,Data1,-1000000,1000000,1,V,0,""'''
  
R1=1,Data1,-1000000,1000000,1,V,0,""
+
'''R2=2,Data2,-1000000,1000000,1,V,0,""'''
  
R2=2,Data2,-1000000,1000000,1,V,0,""
+
 
 
 
;tag = offset, name, min, max, precision, unit, data type, lua script
 
  
 
+
''';tag = offset, name, min, max, precision, unit, data type, lua script'''
  
 
 
 
 

Revision as of 04:35, 28 December 2017

SNTest.exe is a demo program to show how to use EIService SDK API to do a Modbus data read action from Modbus register or data write action to the register.

 

1. Start ModSim32 and configure the register for the demonstration:

  • Set Holding Register data address: 0001 (From first Holding Register address)
  • Set Length: 8
  • Set data from address 40001 ~ 40008, for example 101, 102 , 103 …


  
Modsim32 01.png


2. Enable Modbus Plugin with below settings for the demonstrations:

[Platform]

Name=WISE-4012E

Protocol=Modbus_TCP

ClientIP=127.0.0.1

ClientPort=502

UnitID=1

Interval=1

#Interval: The time delay between two modbus access round in second.

Delay=0

#Delay: The time delay between two modbus access in millisecond.

#Delay=0 means no delay.

Log=0

 

[Holding Registers]

numberOfR=3

R0=0,Data0,-1000000,1000000,1,V,0,""

R1=1,Data1,-1000000,1000000,1,V,0,""

R2=2,Data2,-1000000,1000000,1,V,0,""

 

;tag = offset, name, min, max, precision, unit, data type, lua script

 

3. Run SNTest.exe and select 5) Set Service’s Action.


 

 

4. To do a data Write Demonstration, please set the Service Name, Plugin Name, Sensor Name, Data Type and the value of Data that you want to write.

    For example:

Service Name: Modbus_Handler

Plugin Name: Modbus_Handler

Sensor Name: Modbus_Handler/Holding Registers/Data0

Data Type: v

Data: 66

 

    After completed the procedure, the numbers will be written into assigned variable by EIService SDK function.

 


  

5. You can check ModSim32 screen to confirm the procedure of data write.

 


 