Difference between revisions of "Modbus Handler Service+ EIServiceSDK"

From ESS-WIKI
Jump to: navigation, search
Line 19: Line 19:
  
  
*
+
*<font face="Droid Sans, sans-serif"><font size="3">'''Set Holding Register data address: 0001 (From first Holding Register address)'''</font></font>
<font face="Droid Sans, sans-serif"><font size="3">'''Set Holding Register data address: 0001 (From first Holding Register address)'''</font></font>
+
*<font face="Droid Sans, sans-serif"><font size="3">'''Set Length: 8'''</font></font>
 +
*<font face="Droid Sans, sans-serif"><font size="3">'''Set data from address 40001 ~ 40008, for example 101, 102 , 103 …'''</font></font>
  
*
 
<font face="Droid Sans, sans-serif"><font size="3">'''Set Length: 8'''</font></font>
 
  
*
+
 
<font face="Droid Sans, sans-serif"><font size="3">'''Set data from address 40001 ~ 40008, for example 101, 102 , 103 …'''</font></font>
+
&#x5B;&#x5B;File:|720x406px&#x5D;&#x5D;
 +
 
  
  
  
[[File:|720x406px]]
 
  
  
Line 101: Line 100:
  
 
#
 
#
 +
 
<font face="Droid Sans, sans-serif"><font size="3">Run SNTest.exe and select item 5) Set Service’s Action.</font></font>
 
<font face="Droid Sans, sans-serif"><font size="3">Run SNTest.exe and select item 5) Set Service’s Action.</font></font>
  
  
  
[[File:|714x444px]]
+
&#x5B;&#x5B;File:|714x444px&#x5D;&#x5D;
  
  
Line 113: Line 113:
  
 
<ol start="2">
 
<ol start="2">
<li>
+
<li><font face="Droid Sans, sans-serif"><font size="3">To do a data Write Demonstration, please set the Service Name, Plugin Name, Sensor Name, Data Type and the value of Data that you want to write, for example</font></font></li>
<font face="Droid Sans, sans-serif"><font size="3">To do a data Write Demonstration, please set the Service Name, Plugin Name, Sensor Name, Data Type and the value of Data that you want to write, for example</font></font>
 
</li>
 
 
</ol>
 
</ol>
  
Line 136: Line 134:
  
  
[[File:|812x465px]]
+
&#x5B;&#x5B;File:|812x465px&#x5D;&#x5D;
  
  
Line 144: Line 142:
  
 
<ol start="3">
 
<ol start="3">
<li>
+
<li><font face="Droid Sans, sans-serif"><font size="3">You can check ModSim32 screen to confirm the procedure of data write.</font></font></li>
<font face="Droid Sans, sans-serif"><font size="3">You can check ModSim32 screen to confirm the procedure of data write.</font></font>
 
</li>
 
 
</ol>
 
</ol>
  
  
  
[[File:|683x463px]]
+
&#x5B;&#x5B;File:|683x463px&#x5D;&#x5D;
  
  
  
 
<font face="Droid Sans, sans-serif"><font size="3">(End)</font></font>
 
<font face="Droid Sans, sans-serif"><font size="3">(End)</font></font>

Revision as of 08:02, 28 December 2017

Overview


SNTest.exe is a demo program to show how to use EIService SDK API to do a Modbus data read action from Modbus register or data write action to the register.




Modbus Simulator


Start ModSim32 and configure the register for the demonstration:


  • Set Holding Register data address: 0001 (From first Holding Register address)
  • Set Length: 8
  • Set data from address 40001 ~ 40008, for example 101, 102 , 103 …


[[File:|720x406px]]







WISE Agent and Modbus Plugin


Configure Modbus Plugin settings (Modbus_Handler.ini) as showed below for the demonstrations:


[Platform]

Name=WISE-4012E

Protocol=Modbus_TCP

ClientIP=127.0.0.1

ClientPort=502

UnitID=1

Interval=1

#Interval: The time delay between two modbus access round in second.

Delay=0

#Delay: The time delay between two modbus access in millisecond.

#Delay=0 means no delay.

Log=0


[Holding Registers]

numberOfR=3

R0=0,Data0,-1000000,1000000,1,V,0,""

R1=1,Data1,-1000000,1000000,1,V,0,""

R2=2,Data2,-1000000,1000000,1,V,0,""


;tag = offset, name, min, max, precision, unit, data type, lua script




Demo Program


Run SNTest.exe and select item 5) Set Service’s Action.


[[File:|714x444px]]




  1. To do a data Write Demonstration, please set the Service Name, Plugin Name, Sensor Name, Data Type and the value of Data that you want to write, for example


Service Name: Modbus_Handler

Plugin Name: Modbus_Handler

Sensor Name: Modbus_Handler/Holding Registers/Data0

Data Type: v

Data: 66


After completed the procedure, the numbers will be written into assigned variable by EIService SDK function.


[[File:|812x465px]]




  1. You can check ModSim32 screen to confirm the procedure of data write.


[[File:|683x463px]]