AFE-E420 COM

From ESS-WIKI
Revision as of 08:57, 13 June 2025 by Seven.lin (talk | contribs) (Created page with "AFE-E420 Connector COMABCD AFE-E420 Connector ISO COM == '''COM GPIO Definations''' == {|...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

AFE-E420 Connector COMABCD



AFE-E420 Connector ISO COM

COM GPIO Definations

COM MODE0 MODE1 DEV
A 453 452 /dev/ttyLP0
B 457 456 /dev/ttyLP3
C 499 500 /dev/ttyUSB0
D 503 504 /dev/ttyUSB1
ISO_Top 440 441 /dev/ttyUSB2
ISO_Bottom 447 446 /dev/ttyUSB3

RS-232

Set MODE0 to 1 and MODE1 to 0 for RS-232.

# echo ${MODE0} > /sys/class/gpio/export
# echo ${MODE1} > /sys/class/gpio/export
# echo out > /sys/class/gpio/gpio${MODE0}/direction
# echo out > /sys/class/gpio/gpio${MODE1}/direction
# echo 1 > /sys/class/gpio/gpio${MODE0}/value
# echo 0 > /sys/class/gpio/gpio${MODE1}/value

RS-422

Set MODE0 to 1 and MODE1 to 1 for RS-422.

# echo ${MODE0} > /sys/class/gpio/export
# echo ${MODE1} > /sys/class/gpio/export
# echo out > /sys/class/gpio/gpio${MODE0}/direction
# echo out > /sys/class/gpio/gpio${MODE1}/direction
# echo 1 > /sys/class/gpio/gpio${MODE0}/value
# echo 1 > /sys/class/gpio/gpio${MODE1}/value

RS-485

Set MODE0 to 0 and MODE1 to 1 for RS-485.

# echo ${MODE0} > /sys/class/gpio/export
# echo ${MODE1} > /sys/class/gpio/export
# echo out > /sys/class/gpio/gpio${MODE0}/direction
# echo out > /sys/class/gpio/gpio${MODE1}/direction
# echo 0 > /sys/class/gpio/gpio${MODE0}/value
# echo 1 > /sys/class/gpio/gpio${MODE1}/value

Test Command

Receive Data

# stty -F ${DEV} speed 115200 ignbrk -brkint -icrnl -imaxbel -opost -onlcr -isig -icanon -iexten -echo -echoe -echok -echoctl -echoke
# cat ${DEV} &

Send Data

# stty -F ${DEV} speed 115200 ignbrk -brkint -icrnl -imaxbel -opost -onlcr -isig -icanon -iexten -echo -echoe -echok -echoctl -echoke
# echo "Serial Port Test" > ${DEV}