Attention

Account & Password

Account number

ubuntu

In device used "sudo" or "sudo su" to root. Password required.

ubuntu

Burnin HW Setting

1. Device A Can port link Device B Can port
2. Com1 port link Loop back
3. Lan1 link Lan2

Burnin SW Setting

Screen Blank setting

Please in OS setting Power
Power --> Power Saving Options --> Screen Blank --> Never
Screenshot from 2025-08-13 01-42-01.png

Lan setting

Please in OS setting Network
Screenshot from 2025-08-12 09-17-33.png
Delete all ethernet first
Details --> Remove Connection Profile
Screenshot from 2025-08-13 05-23-09.png
Intel Ethernet --> IPv4 --> Manual
Addresss: 192.168.0.1 | Netmask: 255.255.255.0
--> Apply
Screenshot from 2025-08-12 09-17-43.png
Realtek Ethernet --> IPv4 --> Manual
Addresss: 192.168.0.11 | Netmask: 255.255.255.0
--> Apply
Screenshot from 2025-08-12 09-17-52.png

Manual testing

$ ping -I 192.168.0.1 -O -D 192.168.0.11

Burnin

In first time setting Burnin tool

$ cd /usr/local/bin/Burnin
$ sudo tar -zxvf Burnin_air021.tar.gz
$ cd Burnin_air021

Please link on network to upgrade tool

$ sudo ./install.sh

In device A please run command below

$ cd /home/ubuntu
$ sudo ./Burnin_AIR021_A.sh

In device B please run command below

$ cd /home/ubuntu
$ sudo ./Burnin_AIR021_B.sh

EMI Burnin

EMI colorbar In device please run command below

$ cd /home/ubuntu
$ sudo ./Burnin.sh

Reference

AIR-021 Development